Xylem EPR IM Electric heater-circulator unit EPR (obsolete) User Manual
Page 5

5
Instruction manual Laing Electric heater circulator unit
www.lainginc.com
The Electric heater circulator units EPR 6 to EPR 15 differ only in the perfor-
mance of the electrical heating elements and the distance between the ports.
EPR 6 has a heating performance of 6000 W, EPR 9 has 9000 W, EPR 1
has 1000 W and EPR 15 has 15000W.
The control unit, which controls a variety of control and safety functions, is
arranged on top of the Electric heater circulator.
Technical Data
Model
EPR
EPR
EPR
EPR
6
9
12
15
Pmax.
87 PSI
Tmax.
194°F
Connection on water side
Union 1” male
Weight
1.8 lb .5 lb 3.8 lb 4.5 lb
Pump
Max. Head
4.6 PSI
Max. Flow
14.9 GPM
Motor
Design
Shaftless spherical motor
Watts Input
99 W
Motor performance
35W
Volts AC
30 V
Amperes
0.43 A
Electric Heater
Electrical performance
6 kW
9 kW
1 kW
15 kW
Number of heating elements
3
3
3
3
Heat capacity per element
kW
3 kW
4 kW
5 kW
Voltage
400 V, 3P 400 V, 3P 400 V, 3P 4 0 0 V,
3P
Amperes
8.7 A
13.0 A
17.4 A
1.6 A
Connection
Y
Y
Y
Y
Safety Temperature Limiter
Maximum temperature
03°F+/- 5 K