Instruction manual Laing Electric heater circulator unit

www.lainginc.com

The Electric heater circulator units EPR 6 to EPR 15 differ only in the perfor-

mance of the electrical heating elements and the distance between the ports.

EPR 6 has a heating performance of 6000 W, EPR 9 has 9000 W, EPR 1

has 1000 W and EPR 15 has 15000W.

The control unit, which controls a variety of control and safety functions, is

arranged on top of the Electric heater circulator.

Technical Data

Model

EPR

EPR

EPR

EPR

6

9

12

15

Pmax.

87 PSI

Tmax.

194°F

Connection on water side

Union 1” male

Weight

1.8 lb .5 lb 3.8 lb 4.5 lb

Pump

Max. Head

4.6 PSI

Max. Flow

14.9 GPM

Motor

Design

Shaftless spherical motor

Watts Input

99 W

Motor performance

35W

Volts AC

30 V

Amperes

0.43 A

Electric Heater

Electrical performance

6 kW

9 kW

1 kW

15 kW

Number of heating elements

3

3

3

3

Heat capacity per element

 kW

3 kW

4 kW

5 kW

Voltage

400 V, 3P 400 V, 3P 400 V, 3P 4 0 0 V,

3P

Amperes

8.7 A

13.0 A

17.4 A

1.6 A

Connection

Y

Y

Y

Y

Safety Temperature Limiter

Maximum temperature

03°F+/- 5 K