Instruction manual Laing Electric heater circulator unit

www.lainginc.com

Connection EPR series

Heating

loop return

side

Mounting

eyelet

Connection

for expansi-

on tank

Air vent

Safety relief

valve

Heating

loop feed

side

Mounting

eyelet

Mounting

eyelet

Mounting

For safety reasons, the Electric heater circulator must be mounted on a

fireproof base. In addition, the unit must be installed with the circulator

motor pointing downwards!

The unit must be attached to a flat wall with the help of the mounting eyelets

arranged at the top of the unit and at the pump housing. To avoid noise trans-

fer to the wall, both sides of the mounting eyelets have to be covered with

rubber insulators. The rubber insulators are supplied with the Electric heater

circulator unit and have to be mounted in such a way that no metal contact

exists between the castings and the fastening screw. In addition, no part of

the Electric heater circulator unit - for example the outer shell or the pump

- should be in contact with the wall.

The Electric heater circulator should be mounted at least .4’’ above the

floor to allow replacement of the circulator motor if necessary.

Connection to the feed and return line
The unit is connected to the hea-

ting loop by 1” male threaded fit-

tings. The feed line is at the top of

the unit, the return line at the bot-

tom. The expansion tank should

be connected to the 3/8” port next

to the return line. If the expansion

tank cannot be connected there, it

should be connected somewhere

else in the return line, but not in

the feed line. There are two ˝”

ports at the top of the unit. The

automatic air vent for the heating

circuit is connected to the ˝” port

closest to the wall, the pressure

relief valve to the port in front.

When the Electric heater cir-

culator unit is used solely for floor

heating, the chapter “Important

Notice: Proper connection to a

floor heating system” has to be

observed.