Instruction manual Laing Electric heater circulator unit

www.lainginc.com

Indirect domestic hot water heating with the Electric heater-circulator

EPR

Indirect domestic hot water heating

During the heating period the heating of the domestic hot water normally

is performed by the domestic hot water heater that is essentially a heat

exchanger. When hot water is needed, the water from the hydronic heating

circuit is conveyed through this heat exchanger by activating the hot water

heater priority circuit control. This means that the circulator for the heating

circuit is shut off and the charging circulator for the domestic hot water heater

is switched on. In addition the temperature of the boiler will be increased to

the temperature necessary to heat the domestic hot water.

However, this system can only be operated economically during the hea-

ting period. Outside the heating period it is uneconomical to run the boiler

just for heating of the domestic hot water. Therefore it is customary, to have

an electric heating element beside the heat exchanger within the boiler that

heats the domestic hot water outside the heating period.

This method is problematic when the water is extremely corrosive or when

the water is hard. It is possible that the heating elements survive only a few

month in such a situation.

In these cases it is advantageous to heat the hot water heater outside the

heating period also with electricity but indirectly via the Electric heater-circu-

lator EPR that is ideal for this application.

By adding an additional printed circuit the Electric heater-circulator EPR

can easily be integrated into existing controls.

Starting operation of the domestic hot water heating and adaptation to

seasonal change

To start the Electric heater-circulator the constant temperature has to be set

to the desired value, normally about 158°F. The circulator then has to be swit-

ched to time delay (close jumper 5) for the switching sequence of the heating

elements D, which means, jumper 1, and 3 must be open, jumper 4 has to

be closed. Now the Electric heater-circulator is ready for operation.

To change to the heating season when the boiler is in operation, the main

switch has to be shut off while outside the heating season the main switch

has to be turned on. In this latter case the heating of the domestic hot water

is performed by the Electric Heater-circulator. Even outside the heating period

the boiler control has to stay operational.