Instruction manual Laing Electric heater circulator unit

www.lainginc.com

Applications

Electric heater circulator units Model EPR can be applied in all cases where

electric heating has to be installed in a small space to heat an apartment or

a single or multiple family house.

This applies to direct electrical heating as well as for electrical heating with

a heat storage.

A further application exists in connection with room additions where the

electric heating can supplement the existing hydronic heating.

The Electric heater-circulator is also very well suited to heat domestic

hot water. The application for heating of domestic hot water is described in

“Indirect domestic hot water heating - Application”.

Design of the EPR model

The Electric heater circulator model EPR consists of a circulator pump, an

electric heater with three heating elements and an electronic microprocessor

control.
The spherical motor circulator

operates almost noiselessly and stays

quiet over its lifetime.

The arrangement of the pump be-

low the heating elements guarantees

good heat conductivity from the hea-

ting elements since the swirl created

by the impeller extends over the length

of the heating elements. This avoids

overheating of the heating element

surfaces.

The water for the heating loop is drawn

in by the circulator, conveyed along

the heating elements and discharged

through the discharge port at the

upper part of the housing. The inlet

has an additional 3/8” port, to which

an expansion tank can be connected.

An automatic air vent and a pressure

relief valve communicate with the

outlet port.

Mounting eyelets are included in

the castings of the unit.