Instruction manual Laing Electric heater circulator unit

www.lainginc.com

to avoid a further overheating. However, it may not be possible to switch it

on again since the high temperatures may have destroyed the element. This

damage is recognizable when the knob of the switch for the safety temperature

limiter cannot be engaged any more. If this is the case, the safety temperature

limiter has to be replaced.

Important Notice: For proper connection to a floor heating system

All parts of the Electric heater-circulator and all other components which are

part of the Laing compact- or central stations, which come in contact with the

liquid conveyed are corrosion resistant. Therefore it is possible to provide

a direct floor heating system connection even if the pipes are not diffusion

protected.

However, this applies only when the whole floor heating loop consists of

corrosion resistant material. In any case installations having corroding mate-

rials such as iron expansion tanks, iron pipes or radiators should be avoided.

In such installations – even when they are diffusion protected – excessive

corrosion will occur in a short time on the iron parts which in turn can lead to

other damages and even water leaks in the system. In these systems only a

separation between the systems can solve the problem.

Factory settings

Constant temperature control

1°F

Safety temperature cutout

140°F

Jumper 1

closed

Jumper 

open

Jumper 3

open

Jumper 4

open

Jumper 5

open

Jumper 6

closed

Jumper 7

closed

Jumper 8

closed