Reset Modes

The TLP 710CV has four reset modes that correspond to four of the five reset modes for
the IP Link controllers. The modes are initiated by pressing the Reset button.
To access the Reset button on the TLP 710CV, remove the faceplate.

TLP 710CV Reset Mode Summary

Mode Activation

Result

Purpose and

Notes

Use Factory Firmwar

e

1

Hold down the recessed Reset
button while applying power to the
TLP 710CV.

NOTE:

After a mode 1 reset

is performed, update the
TLP 710CV firmware to the
latest version. Do not operate
the firmware version that
results from this mode reset.
To use the factory default
firmware, reload that version.
See page 25 for details about

uploading firmware

.

The TLP 710CV reverts to the factory default
firmware.
Event scripting does not start if the
TLP 710CV is powered on in this mode. All user
files and settings (drivers, adjustments, IP settings,
etc.) are maintained.

NOTE:

If you do not want to update firmware

or you performed a mode 1 reset by
mistake, cycle power to the TLP 710CV
to return to the firmware version that
was running before the mode 1 reset.
Use the 0Q SIS command to confirm that
the factory default firmware is no longer
running (look for asterisks following the
version number).

This mode reverts to the
factory default firmware
version if incompatibility
issues arise with
user-loaded firmware.

NOTE:

User-defined

web pages
may not work
correctly if using
an earlier version
of the firmware.

Run or Stop

Events

3

Hold down the Reset button for
approximately 3 seconds until the
Release LED blinks once. Then release
and press Reset momentarily (less
than 1 second) within 1 second.

This mode turns events on or off.

NOTE:

Nothing happens if the momentary

press does not occur within 1 second.

This mode is useful for
troubleshooting.

Reset all IP

Settings

4

Hold down the Reset button for
approximately 6 seconds until the
Release LED blinks twice (at 3 seconds
and 6 seconds). Then release and
press Reset momentarily (less than
1 second) within 1 second.

NOTE:

Nothing happens if the

momentary press does not
occur within 1 second.

This mode:

Enables ARP capability.

Resets the IP address to the factory default
(192.168.254.254).

Resets the subnet to the factory default.

Resets the gateway address to the factory
default.

Resets port mapping to the factory default.

Turns DHCP off.

Turns events off.

This mode enables
you to set IP address
information, using ARP
and the MAC address.

Reset to

Factory

Defaults

5

Hold down the Reset button for
approximately 9 seconds until the
Release LED blinks three times (at 3,
6, and 9 seconds). Then release and
press Reset momentarily (less than
1 second) within 1 second.

NOTE:

Nothing happens if the

momentary press does not
occur within 1 second.

This mode performs a complete reset to
factory defaults (except the firmware).
It does
everything that mode 4 does and, in addition:

Removes button and touchpanel
configurations.

Resets all IP options

Removes all scheduling options.

Removes and clears all files from the
TLP 710CV.

This mode is useful
to start over with
configuration and
uploading. It also allows
you to replace events.

TLP 710CV • Reset Modes

43

Advertising