Figure 5-13 E1 Direct Card Properties Clock Recovery

The data clock may be generated by the E-QUE card (Local Generated) or taken from the
E1 line. The clock source must be determined before configuration. Select the correct
configuration by clicking on the appropriate radio button.

5.26.5

Codec

E-QUE cards configured as E1 Direct use two cables plugged into ports 1 (top) and 5
(bottom) for the E-QUE card to provide E1 ports. The top cable (Top Half) provides the first
30 ports (1-30) and the bottom cable (Bottom Half) provides the second 30 ports (31 - 60).
The top and bottom cables can be configured to use different Codecs. The Codecs
available are:

• G722 - standard G722 conversion and compression.
• G722 A-Law - uses an A-law algorithm to optimize the G722 codec. This is often

used in European systems.

• G722 µ-Law - uses a µ-law algorithm to optimize the G722 codec. This is often

used in North America and Japan.

Click on the appropriate radio button to select the codec for top and bottom cables.

5.27

T1 direct

The T1 Direct is an E-QUE card that has been configured for 48 direct ports using T1
protocol. Each T1 port can be used as an E1 communication line to another T1 device.
The following section provides guidance on configuring an T1 Direct in Cards and Ports.

5.27.1

Port function

This is always set to T1 Direct.

5.27.2

Label

Label for the port used to assign the port to a path. The label has 10 characters, or can be
split into two parts, each of maximum five characters.

5.27.3

Description

Optional port description, up to 255 characters long.