Clear-Com HX System Frames User Manual

Page 141

Advertising
background image

1)

From the Configuration menu select the Partylines link. This opens the Partylines
configuration screen.

Figure 5-46 Partyline Setup Screen

2)

Select the New button at the bottom left of the Partylines window.

3)

Change the partyline label and description fields with more meaningful identifiers.

4)

To add permanent fixed members, select the required member in the Available
pane.

5)

Click on the > button to transfer the member to the Attached pane.

6)

Right-click on a member in the ‘Attached’ pane to open a configuration menu and
select whether the attached member is Talk, Listen or Talk and Listen.

The partyline label can be programmed onto a panel key.

The # button on the Available and Attached panes sorts the members by port number in
ascending or descending order, preceded by non-port items such as controls.

The Label button sorts the members by name alphabetically and the Description button
sorts the members alphabetically by description.

The tabs above the Available and Attached panes filter the members by type.

Once a partyline is created, a system must be downloaded to utilise that partyline. It is not
sufficient to only download to the matrix that hosts the partyline (for example, use
Production Maestro Pro to assign members from the entire linked set to the partyline.

The recommended use of this feature is that all partylines are configured and then a
download to all matrices is carried out. The Production Maestro Pro software can then be
used to manipulate these partylines in an online fashion.

141

Eclipse EHX Software User Guide

Advertising
This manual is related to the following products: