3.2 DIP-Switch Settings for 4405 Circuit Board

Switch

Function

Setting

Description

SW 1 (Top 8 Switches)

Primary

Operator

Opening

Direction

OFF

ON

OFF

ON

OFF

ON

OFF

ON

7-OFF
7-OFF

7-ON
7-ON

8-OFF

8-ON

8-OFF

8-ON

Auto-Close

Timer

Single Operator

Dual Operators

Relay

1

2

3

4

5

6

7 and 8

The output wired to terminal #4 becomes the output from the exit loop detector
plugged into the EXIT Loop port.
Normal Setting. Terminal #4 is a normal full open input.

Auto-close timer is OFF. Manual input required to close gate.
Normal Setting. Auto-close timer is ON. Adjustable from 1-23 seconds.

Normal Setting. Switch must be OFF for single operator.
Switch must be ON when primary/secondary (dual) gates are used.

Normal Setting. Relay activates when gate is at open limit.
Relay activates when gate is not closed.
Relay activates when gate is opening and open.
Relay activates during opening and closing cycle.

Switch

Function

Setting

Description

SW 2 (Bottom 4 Switches)

Normal Setting. Switch 3 MUST be turned ON for Model 9000 operator.
Normal Setting. Switch 4 MUST be turned OFF for Model 9000 operator.

OFF

ON

OFF

ON

ON

OFF

Magnetic lock

1

2

3

4

Normal Setting. Magnetic lock is not used.
Magnetic lock is used and connected to terminals 9 and 12. See page 32 for wiring.

Opening direction

using ON setting.

Opening direction
using OFF setting.

Changes direction operator will cycle open
upon initial AC power up and open command.

Changes direction operator will cycle open
upon initial AC power up and open command.

Opening direction

using ON setting.

Opening direction
using OFF setting.

Secondary

Operator

Opening

Direction

Reverses Gate

Stops Gate

Quick-Close

Timer Override

Exit Loop Port

Output

Full Open Input

Normal Setting. Input to terminal #6 and reverse loop will reverse gate during
close cycle.
Input to terminal #6 and/or reverse loop will stop gate during close cycle – gate will
continue to close after input to terminal #6 and/or reverse loop are cleared (Helps
prevent tailgating).

The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then
turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator.

Normal Setting. Timer will function normally.
Opening gate will stop and begin to close as soon as all reversing inputs (Reverse
loops, photo sensors) are cleared regardless of the distance the gate has opened.