1 terminal descriptions, Pin main terminal, Pin non-removable terminal – Controlled Products Systems Group 9000-080 User Manual

Page 33

Advertising
background image

9000-065-F-9-10

31

5.1 Terminal Descriptions

Low Voltage Common

Full Open

24 VAC - 250 mamp. max.

Full Open

Partial Open

Standard Reverse or Stop

Gate Tracker Data

Gate Tracker Busy

24 VDC Mag Lock Power

Dry Relay Contact

Dry Relay Contact

Low Voltage Common

Low Voltage Common

Entrapment Alarm

Alarm Reset

Secondary Current Sensor

Motor

Motor

Circuit Board Power

Circuit Board Power

24-volt DC magnetic lock
power is provided constantly
except when the gate is
opening or open (Normally
Closed function). 1 Amp Max.

DANGER

HIGH VOLTAGE!

For long gate applications. An input
device connected to terminal #5 will
open the gate to the partial open setting,
See page 24 for more information.

DoorKing’s Remote alarm reset
station can be connected. See
next page for wiring.
It MUST be mounted in the
line-of-sight of the gate
operator. (DKS P/N 1404-080)

For dual operator applications
ONLY.
Allows the secondary
reversing sensor to monitor
the current flow into the
secondary operator. See page
26 for more information.

lf SW 1, switch 3 is ON, functions as a

normal full open input (Normal setting).

lf SW 1, switch 3 is OFF, input to

terminal #4 becomes the output from the
EXIT loop detector plugged into the EXIT
loop port. (Used for specialized functions).

SW 1

1

ON

2

3

4

5

6

7

8

Operation of relay is dependent on
setting of SW 1, switches 7 and 8.
Relay contacts can be set for
Normally Open (NO) or Normally
Closed (NC) operation.

Contact rating is
1 amp maximum
at 24-volts DC.

NO

NC

SW 1

1

ON

2

3

4

5

6

7

8

SECTION 5 - MAIN TERMINAL WIRING

This input ONLY fuctions when gate is fully

opened or in the closing cycle.

When gate is closing: SW 1, switch 5 is OFF,

an input to terminal #6 (eg: photo beam gets
obstructed) will reverse and open the gate.
Note: If the auto-close timer is ON,
when gate reaches the open position,
timer will not close the gate. Another
input command is needed to reset
and close the gate.

When gate is closing: SW 1,

switch 5 is ON, an input to terminal
#6 (eg: photo beam gets obstructed)
will stop the gate, then continue to close the
gate when input is clear (Used to help prevent
tailgating vehicles from unauthorized entry).
See page 23 for more information.

SW 1

1

ON

2

3

4

5

6

7

8

Open LED

Close LED

Stop LED

Open N.O.
Close N.O.
Stop N.C.
Common

4-Pin Non-Removable Terminal

20-Pin Main Terminal

1
2
3
4

Jumper on bottom
2 pins when using
4-pin terminal.

Jumper on top 2 pins
when NOT using
4-pin terminal.

Notes:

Use a standard 4-wire 3-button

control station.
DoorKing’s 3-wire 3-button
control station cannot be used.

When using a 3-button control

station AND a interlock device
together, #3 terminal (N.C.) must
be wired in series.

See next page for wiring.

3-Pin with

Jumper

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1

ON

2

3

4

1

ON

SELF
TEST

NC

TIME
DELAY

NO

REV SENSE
PRIMARY

1

2

3

4

5

6

7

8

9

13

12

11

10

14

15

16

17

18

19

20

2

3

4

5

6

7

8

4405-010

9

Relay

Contacts

4

1
2
3

4

5

6

9

10
11

16

15

14