Pin ul 325 terminal – Controlled Products Systems Group 9000-080 User Manual

Page 29

Advertising
background image

9000-065-F-9-10

27

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1

ON

SW 1

2

3

4

1

ON

SW 2

REVERSE
LOOP

P2

P8

EXIT
LOOP

SELF
TEST

NC

TIME
DELAY

NO

REV SENSE
PRIMARY

REV SENSE
SECONDARY

1

2

3

4

5

6

7

8

9

13

12

11

10

14

15

16

17

18

19

20

2

3

4

5

6

7

8

4405-010

Note: The 6-pin terminal can be unplugged
from circuit board for easy wire connections.

All inputs are normally open (NO).

6-Pin UL 325 Terminal

Secondary Entrapment Protection Device Connection

115 VAC Convenience Outlets

Secondary Entrapment Protection Devices:

In addition to the inherent reversing sensor system, the Model 9000 has a 6-pin UL 325 terminal for the connection of photo sensors-Type B1
and reversing edges-Type B2 secondary entrapment protection devices required by UL 325 standards. Entrapment protection devices must
be installed
to reduce the risk of injury. Install these devices where the risk of entrapment or obstruction exists while the gate is moving.
The Model 9000 offers numerous options to meet your specific needs. The next 2 pages show wiring and typical positioning of the entrapment
protection devices but specific installations will vary.

Note: Secondary entrapment protection devices will open the gate to the “Partial Open” setting when the opening device is connected to main
terminal #5 (See page 32 for opening device wiring information).

OPEN Entrapment Sensor

CLOSE Entrapment Sensor

OPEN Contact Sensor

CLOSE Contact Sensor

Low Voltage Common

Low Voltage Common

SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION

4.1 UL 325 Terminal Description

1
2
3
4
5
6

Closed Gate

Wall / Fence

Opening-Direction Photo Beam

Wall / Fence

Filler Post if necessary

Gate Support Post if Installed

Closed Gate

Wall / Fence

Closing-Direction Photo Beam

Closed Gate

Wall / Fence

CLOSE Entrapment Sensor (Photo Sensor):

Obstructed

closing-direction photo beam will stop the gate during the
closing-direction only.
Gate will resume the close cycle
when the obstructed photo beam has been cleared.

Closed Gate

Low Voltage Common:

Common terminals for all the secondary entrapment protection device inputs.

CLOSE Contact Sensor (Reversing Edge):

Obstructed closing-direction reversing edge will stop, then reverse the gate to the open position, during the

closing-direction only.

After the gate reverses to the open position, the timer will

automatically close the gate (if it is turned on). If the
closing-direction reverse edge is activated a second time prior to the gate reaching the
close position, the operator will stop and enter a soft shutdown condition (See page 34).

When the closing-direction reversing edge gets obstructed and the gate is traveling back to the open

position and the opening-direction revering edge gets obstructed, the gate will stop and enter a soft shutdown condition (See page 34).

1

2

3

4

5

&

6

OPEN Entrapment Sensor (Photo Sensor):

Obstructed

opening-direction photo beam will stop the gate during the
opening-direction only.
Gate will resume the open cycle
when the obstructed photo beam has been cleared.

OPEN Contact Sensor (Reversing Edge(s)):

Obstructed opening-direction reversing edge(s) will stop, then reverse the gate to the close position during the

opening-direction only.

After the gate reverses to the full close position, any

opening input will cycle the gate again. Note: If the gate is
opening by a time clock and an opening-direction reversing
edge gets obstructed, the gate will return to the closed
position and another input (automatic exit loop, reverse loop. etc.) is needed to cycle the gate open
again.

When the opening-direction reversing edge(s) gets obstructed and the gate is traveling back to the close position and

the

closing-direction reversing edge gets obstructed, the gate will stop and enter a soft shutdown condition (See page 34).

Opening-Direction Reversing Edges

Closing-Direction Reverse Edge

Entrapment Area

Entrapment Area

Entrapment Area

Entrapment Area