9000-065-F-9-10

29

9 V battery operated transmitter mounted on gate.

Wireless Reverse Edge Sample Setup - Single Receiver

Photo Sensor and Wireless Reverse Edge Sample Setup

Closed Gate

Wall

Normally Open

Common

Normally Open

Install Jumper Wire

Common

Normally Open

Normally Open

Common

When either direction reversing edge get obstructed the gate will STOP,
then continue in the same direction after obstructed reversing edge has
been cleared until the gate cycle is complete.

When a reversing edge or photo beam get
obstructed the gate will STOP, then continue
in the same direction after obstructed
reversing edge or photo beam has been
cleared until the gate cycle is complete.

Filler Post Note: Install reversing edges on all
the gate support posts or filler post in this area
(e.g. cantilever gate installations, See below).

Wireless Note: Refer to the
instruction sheet that comes
with the receiver/transmitter
for more specific wiring and
mounting instructions.

Wiring Note: Receiver
can be wired directly to
main terminal if desired.

Wiring Note:
Receiver can
be wired
directly to main
terminal if desired.

Closing-
Direction
Reversing
Edge

Closing-
Direction
Reversing
Edge

Opening-Direction Reversing Edge

6-Pin UL 325 Terminal Wiring

Opening-Direction Reversing Edge (If filler post is used).

9 V battery operated transmitter mounted on gate.

Filler Post

(If necessary)

Edge

Transmitter

Edge

Transmitter

Power is limited
to 250 mamps.

Coax Antenna Kit

P/N 1514-073

Com

Com

24 Volt

3-Pin

Remote

Terminal

Antenna mounted

outside operator cover.

24 VAC Receiver

Place receiver in operator.

1
2

3
4
5
6

6-Pin UL 325 Terminal Wiring

Normally Open

Normally Open

Common

Com

Opening-Direction Photo Beam

Normally Open

Common

Wireless Note: Refer to the
instruction sheet that comes
with the receiver/transmitter
for more specific wiring and
mounting instructions.

24 Volt

24 VAC Receiver

Place receiver in operator.

20-Pin

Main

Terminal

To #1

To #3

Photo Sensor Power Note:
Photo sensors can be powered
by the built-in convenience
outlets located on the operator
(See page 27).

Install Opening-Direction
reverse edges on the gate
support post(s) in this area.

1

2

3
4
5
6

Cantilever Gate

Coax Antenna Kit

P/N 1514-073

Antenna mounted

outside operator

cover.

OPEN Entrapment Sensor

CLOSE Entrapment Sensor

OPEN Contact Sensor

CLOSE Contact Sensor

Low Voltage Common

Low Voltage Common

OPEN Entrapment Sensor

CLOSE Entrapment Sensor

OPEN Contact Sensor

CLOSE Contact Sensor

Low Voltage Common

Low Voltage Common

1

2

3

Power is limited
to 250 mamps.

3-Pin

Remote

Terminal

20-Pin

Main

Terminal

To #1

To #3

1

2

3