2 control wiring, Pin main terminal, Pin non-removable terminal – Controlled Products Systems Group 9000-080 User Manual

Page 34: Pin remote terminal

Advertising
background image

9000-065-F-9-10

32

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

NC

NO

1

2

3

4

5

6

7

8

9

13

12

11

10

14

15

16

17

18

19

20

4

1
2
3

Com

Com

Com

4405-010

PU

SH

TO

O

PE

RA

TE

tec

hn

ici

an

us

e o

nly

Power

Gate Tracker

-

DoorKing Access Control System (Model 1833, 1835, 1837 or 1838)

tracker system can be connected. This system can keep track of gate operator cycle
count, shorted inputs, loop detector problems, any forced entry attempts, if the gate
has struck anything during the open or close cycle, power interruptions, etc. For more
detailed information refer to the Tracker Installation and Wiring Manual, DoorKing P/N
2351-010.
Terminal #2 (Full open) or #5 (Partial open) required only if the tracker board will
activate the gate operator. Refer to the manual 2351-065 for detailed information.

5.2 Control Wiring

Power is limited
to 250 mamps.

Switch 3 Must be ON.

Power (24-Volt DC) and
logic output. Power is shut
off .5 sec. prior to gate
starting and remains off
while gate is opening and
in the open position.

#4 Com

White

24 Volt

1 amp max.

Stand-Alone

Key Switch

Safety

Opening

Device

Stand-Alone

Keypad

Stand-Alone

Card Reader

Telephone

Entry

“Closing-Direction” Photo Sensors

4-Pin Non-Removable Terminal

20-Pin Main

Terminal

Note: All stand-alone
and telephone entry devices must
use a separate power source.

Note: When
using 3-button
control station
AND interlock
switch together,
#3 terminal
(N.C.) must be
wired in series.

Remote Alarm Reset Station

(DKS P/N 1404-080) MUST be mounted
in the line-of-sight of the gate operator.

3-Button Control Station

Use a standard 4-wire 3-button
control station. DoorKing’s
3-wire 3-button control station
cannot be used.

Normally Closed Interlock Switch

SW 1, switch 5: After photo

sensor beam gets obstructed:

OFF- Reverses gate.

Partial

Open

Full

Open

Full

Open

#3 Stop N.C.

#2 Close N.O.

#1 Open N.O.

3-Wire Radio

Receiver

To #4 Com

To #3 Stop N.C.

N.O.

N.C.

Com

Operator Cycling

Lock Engaged

N.O.

N.C.

Com

Operator Stopped

Lock Disengaged

Red

Blue

Alarm

Alarm
Reset

#5 Terminal Note: Any opening device connected to terminal #5 will
open the gate to the partial open setting. Secondary entrapment
protection devices will also open the gate to the partial open setting.
If the inherent reverse sensor gets activated during the close cycle,
it will always fully open the gate.

OPEN

STOP

CLOSE

SW 1

1

ON

2

3

4

5

6

7

8

SW 1

1

ON

2

3

4

5

6

7

8

Com

24 V

olt

Relay

1

Mo

tor

2

Mo

tor

3

Ne

utr

al

4

24

VA

C

5

Limi

t

6

Sp

are

7

Limi

t

8

COM

3-Pin

Remote

Terminal

1

2

3

Place jumper
on bottom
2 pins when
using 4-pin
terminal.

3-Pin With

Jumper

Magnetic Lock

Quad Box

#4 Normally Open

#2 Normally Open

#6 Normally Open

#9 Normally Close

ON -

Stops gate then continues

closing when gate is clear (Same
function as UL 325 terminal #2).
Note: The ON setting is used to help prevent
tailgating but the photo sensor should be wired to
the UL 325 terminal #2 when the “stop gate”
function is desired, see pages 27 and 28 for more
information.

Advertising
This manual is related to the following products: