9000-065-F-9-10

28

Gate Frame

5”

or Less

or Less

Non-Secure Side

Outside Property

Secure Side

Inside Property

Filler Post or Barrier

Reversing Edge (Open Contact Sensor)

4.2 Secondary Entrapment Protection Device Locations

Photo Sensors (With Filler Post and Reverse Edge) Sample Setup

Typical UL Photo Sensor mounting height
and distance away from gate.

Photo sensors may be installed on either side of gate frame.

5”

21”

Typical

Gate Frame

If the distance between the gate
and wall is greater than 2 1/4”.

Wall

UL sensor mounted on post.

UL sensor mounted on wall.

Closed Gate

Wall

Normally Open

Normally Open

Normally Open

Common

Common

Common

Common

Normally Open

A filler post or barrier may need to be installed between the
gate and wall area to reduce the distance to 2 1/4” or less.
A reversing edge should be installed on the post or barrier
for safety (See page 8 for more information).

Photo Sensor Power Note: Photo sensors can be powered by the built-in
convenience outlets located on the operator (See previous page).

IF the closing-direction photo
sensor is wired to the #6 main
terminal, a closing-direction
photo beam that gets obstructed

will REVERSE the gate
back to the open position.

Closing-direction photo sensors wired to UL 325 terminal.

NC

NO

1

2

3

4

5

6

7

8

9

13

12

11

10

14

15

16

17

18

19

20

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

543

2

1

4405-010

Closing-Direction Photo Beam

Opening-Direction Photo Beam

6-Pin UL 325 Terminal Wiring

“Reverse” Closing-Direction Option

SW 1

1

ON

2

3

4

5

6

7

8

1
2
3

4

5
6

Filler Post with Opening-Direction Reversing Edge (If necessary, see above)

OPEN Entrapment Sensor

CLOSE Entrapment Sensor

OPEN Contact Sensor

CLOSE Contact Sensor

Low Voltage Common

Low Voltage Common

SW 1, switch 5
MUST be OFF.

IF the closing-direction photo sensor is wired to the UL 325 terminal, a
closing-direction photo beam that gets obstructed will STOP the gate then
resume closing the gate when the obstructed photo beam has been cleared.