Dwhu – Diamond Products SB User Manual
Page 17
![background image](/manuals/339239/17/background.png)
SB Wire Sawing System
Water
SB_0107_e.mif
Page 17
:DWHU
:DWHU FLUFXLW
The water coming from the drive unit is led to
the water entry nozzle (1) and from there to the
individual points, which have to be cooled and
flushed through.
:DWHU HQWU\
Connect water supply hose from drive to this
point
:DWHU WDS
This regulates the water quantity for flushing
the drive pulleys (B)
:DWHU H[LW WR WKH GULYH SXOOH\V
Lead flexible water supply hose to the drive
pulleys so that they are optimally flushed
:DWHU ODQFHV $
The water lances must be placed into the cut
at the wire entry points so that the wire is
optimally cooled.
&RQQHFW ZDWHU
- Pressure: Min. 1 to max. 6 bar
- Water temperature: Max. 25°C
- Ensure that the water supply is not interrupted during
operation
%ORZ RXW ZDWHU LI WKHUH LV D ULVN RI IURVW
l
Disconnect the water supply hose to the
drive being used
l
Disconnect both water lances (A) and blow
them out
l
Open water tap (2)
l
Blow out the water hoses in the drive unit
hose set
Never connect the water supply hose
directly onto the SB. Instead always lead it
first through the drive unit in order to cool
the electric motor.
Never close the water tap during operation.
To avoid frost damage, if there is a risk of
frost the whole water system must be emp-
tied and blown out after work or before
longer operating breaks.
See also the operating instructions for the
drive unit being used.