Specifications

Models ICS/ICX/FB

9.5

10

15

20

25

30

Boiler Connections

N. Steam Outlet 15 PSI

N/A

1.5”

2”

3”

3”

3”

NPT

NPT CL150# CL150#

CL150#

Flange Flange

Flange

N. Steam Outlet 150 PSI

1”

1”

1.25”

1.5”

2”

2”

NPT

NPT

NPT

NPT

NPT

NPT

O. Safety Valve Outlet 15 PSI

IN

N/A

0.75

1

1.5

1.5

1.5

MM

19

32

38

38

38

O. Safety Valve Outlet 150 PSI+

IN

1

1

1

1

1

1

(9.5 HP 100 PSI)

MM

25

25

25

25

25

25

P. Safety Valve Inlet 15 PSI++

IN

N/A

0.75

1

1.25

1.25

1.25

MM

19

25

32

32

32

P. Safety Valve Inlet 150 PSI

IN

0.75

0.75

0.75

0.75

0.75

0.75

(9.5 HP 100 PSI)

MM

19

19

19

19

19

19

Q. Feedwater Inlet

IN

1

1

1

1

1

1

MM

25

25

25

25

25

25

R. Blowdown Outlet

IN

1

1

1

1.25

1.25

1.25

MM

25

25

25

32

32

32

S. Water Column Blowdown

IN

1

1

1

1

1

1

MM

25

25

25

25

25

25

Ratings* (Sea level to 3000 ft.)
Output

1000 BTU/HR

318

335

503

670

838

1005

1000 KCAL/HR

80.1

84.4

127

169

211

253

Steam Output

LB/HR

328

345

518

690

863

1035

KG/HR

149

157

235

313

392

470

Approximate Fuel Consumption at Rated Capacity+++
Natural Gas (ICS)

FT3/HR

398

419

628

837

1047

1256

(9” - 13” w.c. req’d)

M3/HR

11.3

11.9

17.8

23.7

29.7

35.4

Natural Gas (ICX)

FT3/HR

384

403

606

807

1009

1210

(9” - 13” w.c. req’d)

M3/HR

10.8

11.4

17.2

22.9

28.6

34.3

Natural Gas Boiler

IN

1

1

1

1.25

1.25

1.5

Connection Size (Std CSD-1)

MM

25

25

25

32

32

38

Oil Inlet Size

IN

1/4

1/4

1/4

1/4

1/4

1/4

MM

6

6

6

6

6

6

Burner

3450 RPM/60 CY

Motor HP

2850 RPM/50 CY

.75

.75

1.5

1.5

1.5

1.5

Electric Power Requirements - Burner Only (in Amps) ***
120V,60 CY, 1 Phase

9.2

9.2

--

--

--

--

240V, 50/60 CY, 1 Phase

4.6

4.6

8.9

8.9

8.9

8.9

208V, 50/60 CY, 3 Phase

3.1

3.1

4.4

4.4

4.4

4.4

240V, 50/60 CY, 3 Phase

2.8

2.8

4.2

4.2

4.2

4.2

480V, 50/60 CY, 3 Phase

1.4

1.4

2.1

2.1

2.1

2.1

Water Content

U.S. GAL

16

24

39

77

82

170

LITERS

61

91

148

292

311

644

Specifications and Dimensions are approximate. We reserve the right to change specifications and/or dimensions..+ High pressure boilers purchased with low pressure
openings may have larger than specified opening sizes, consult factory for correct opening sizes.++ 50 and 60 HP have two safety valves on low pressure.
+++Consumption based on Natural Gas 1000 BTU/ft.

3

. *All ratings from 0 PSIG and at 212 degrees F. *** Control circuit electrical requirement will vary with the system

voltage, please consult factory. --Consult factory.

ffsle-pds-2011-1223

The Fulton Companies
972 Centerville Road
Pulaski, NY 13142
Call 315-298-5121
Fax 315-298-6390
www.fulton.com

10-G 1/01