Symptom

Failed Initialization screen test

Cause

• Axis driver card failure
• Limit sensors bad
• Solenoid bad

• Machine has moved past the limit switches

Symptom

LCD screen too light or dark to read

Cause

• Contrast needs adjusted

Refer to page 32

• LCD back light failure

• LCD bad

Symptom

LCD screen displays garbage or grossly

inaccurate information.

Cause

• Machine temperature is too cold/hot – do

not operate until machine temperature

reaches above 7°C (45°F) but not more

than 32°C (90° F)

• Restore calibrations from locked area

• LCD battery is dead
• LCD is bad

Symptom

After pressing “Cycle Start” the machine

does not move into the sharpening cycle

Cause

• Make sure drill has been loaded properly

and sensor button has been depressed

• Close door

• Software has caused machine to hang up –

turn machine off and then on again

• Cycle start switch needs replacement
• Printed circuit board on back of LCD is bad

Symptom

Drill rotates in front of fiber optic sensor

failing to locate cutting edge

Cause

• Old software installed
• Drill diameter is smaller than 3mm

• Drill diameter is of a smaller dimension

with a thick web

• Color of drill is interfering with cutting

edge detection – typically gold or black

drills

Refer to page 61

• False diameter was input or detected in

• Fiberoptic Amplifier Baseline setting has

changed. Contact Darex for instructions.

manual mode

• Cutting edge is broken
• Cutting edge has shinny build up, such as

aluminum

• Surface finish too rough
• Calibration of fiber optic sensor is incorrect

and will need recalibrated

• Fiber optic lens is loose
• Fiber optic sensor needs replaced

• Fiber optic lens needs cleaned or replaced
• Fiber optic cable has been damaged

• Shank is larger than body of drill and cor-

rect diameter has not been manually input.

Example: Step drill

Symptom

Auto diameter detect will not detect cor-

rect diameter

Cause

• Diameter detection rod is bent
• Diameter detection rod has been improp-

erly installed.

Refer to page 47

• Incorrect diameter calibration
• Shank of drill may be larger/smaller than

actually body of drill

• Drill flutes are worn or damaged
• MTO #1 button excessively worn

Symptom

Auto web detection does not display cor-

rect web thickness

Cause

• Fiber optic sensor lens is dirty.

Refer to

page 81

• Fiber optic sensor is not calibrated cor-

rectly

• Fiber optic sensor is bad
• Old software installed

Symptom

Cutting edge is not positioned correctly

at 1:00

Cause

• Chip on cutting edge
• Burr on cutting edge

• The fiber optic sensor has detected the

split line as cutting edge

• Drill has a hook in the cutting edge – use

the Advance Screen to compensate.

Refer

to page 39

• Changing from extreme point angles. Ex-

ample: Converting a 180° drill into a 118°

point angle

• Material build up on cutting edge

• A value left in the Advance Screen

Trouble Shooting Section

Advertising