9. Maintenance/Inspection

Cover

[4] Attach the rubber cover in the case of small

two-finger slide type (RCP2CR-GRSS).

Small two-finger slide type (RCP2CR-GRSS)

Warning

Never use a fluorine grease. If a fluorine grease is mixed with a lithium grease, the lubricating

function of grease will drop and the machine may suffer damage.

Do not use spray oil. Be sure to use spray grease. Keep the spray time to a maximum of 1 second,

and never spray more than twice. If too much grease is applied, excess grease may flow into the
electronic components and cause malfunction.

Warning

The encoder phase has been precisely adjusted to ensure accurate detection of rotational angle and

home signal. To prevent malfunctioning, never touch the encoder.

Caution

In case the grease got into your eye, immediately go to see the doctor to get an appropriate care.
After finishing the grease supply work, wash your hands carefully with water and soap to rinse
the grease off.