14. Motor Replacement Procedures

75

(5) Removing the motor unit

[1] Loosen the coupling tightening bolt.

Caution: If the actuator is installed vertically, exercise due

caution not to let the slider drop.

Hold the slider (work part) from the outside to

prevent it from dropping, and then loosen

the coupling bolt.

Remove the bolts used to secure the motor using an Allen wrench of 4 mm across flats, and pull out the

motor unit and coupling from the motor housing.

Motor affixing bolt

Motor affixing bolt

Motor affixing bolt

Motor affixing bolt

Motor

Body