IAI America SSPA User Manual

Page 91

Advertising
background image

14. Motor Replacement Procedures

83

(4) Installing the motor temporarily

[1] With the motor servo turned on, fit the motor unit’s coupling in the end of the ball screw shaft and fasten the

motor housing and motor unit temporarily. (Tighten manually for this temporary purpose.)

When fastening the motor and motor housing temporarily, be sure to place them next to each other with no

gaps or play.

If the cable exits from the right, install the motor as shown in the photograph below so that the motor cable is

positioned on the left side. If the cable exits from the left, install the motor in the position opposite of the

photograph.

Caution: The cable exit direction must be the same for the motor to be removed and new motor to be

installed.

If the cable exit direction is different on the installed motor, deviation of the home position will

occur.

Type

Bolt used

ISB, ISPB

SXM/SXL

M4 x 12

ISB, ISPB

MXM/MXL/

MXMX

LXM/LXL/LXMX/

LXUWM

M5 x 15

SSPA

SXM

M5 x 15

SSPA

MXM

M5 x 15

SSPA

LXM

M6 x 20

Four bolts used to secure the motor