Specifications – LEESON FHP Series Chassis Mount Variable Speed Drives User Manual

Page 11

Advertising
background image

1

Specifications

1-Phase

1 or 3-Phase

Max Continuous

AC

Input

Output

Max

Output

Amps

Drive

(VAC)

(VAC)

HP

Current (AC)

In

175318

230

230

¼

1.2

3

175319

*

115 / 230

230

¼

1.2

7 / 3

175320

115

115

¼

2.4

7

175321

230

230

½

2.4

7

175310

*

115 / 230

230

½

2.4

10 / 7

175322

115

115

½

4.0

10

175323

230

230

1

4.0

10

175311

*

115 / 230

230

1

4.0

15 / 10

*

Connect only 115 VAC line input to the 115 VAC terminals. Application of 230 VAC line input when set for 115

VAC will result in severe damage to the motor and drive, and possible explosion and injury.

† Derate current by 2% per degree if the operating temperature is above 40°C. Under no circumstances may the

ambient temperature exceed 55° C.

AC Voltage Input Range

175320 & 175322

115 VAC ± 10%, 50/60 Hz single phase

175318, 175321, & 175323

230 VAC ± 10%, 50/60 Hz single phase

175319, 175310, & 175311

115/230 VAC ± 10%, 50/60 Hz single phase

Standard Carrier Frequency

16 KHz

Output Frequency Range

0 – 120 Hz

Adjustable Maximum Output Frequency Range

30 – 120 Hz

Acceleration Time Range

1 – 12 seconds

Deceleration Time Range

1 – 12 seconds

Analog Input Voltage Range (signal must be isolated; S1 [-] to S2 [+])

0 – 5VDC**

Input Impedance, S1 to S2

~ 100K ohms

Vibration

0.5G max (20 – 50 Hz)

0.1G max (> 50 Hz)

Weight

1.2 lb

Ambient Operating Temperature Range

10° – 40° C

** An isolation board option that allows for a non-isolated 0 - 5 VDC, 0 - 10 VDC, or 4 - 20 mA input signal is

available (-PCM option). The option board is installed directly above the main board, maintaining the same

footprint and dimensions. Call the factory for more information regarding the -PCM option.

Advertising