Problem possible cause suggested solution – LEESON FHP Series Chassis Mount Variable Speed Drives User Manual

Page 71

Advertising
background image

61

Troubleshooting

1. Increase MAX SPD

setting (page 46).

2. Compare motor

voltage to input
voltage; replace
motor if necessary

3. Check motor load.

Resize the motor or
drive if necessary.

1. Make sure motor is

not undersized for
load; adjust TQ LIM
setting CW (page
47).

1. Check DIRECTION

switch connection.

2. Check reversing

circuit by shorting
TB501 (D) terminal
to (E1) terminal
with jumper wire.

Motor will not reach the
desired speed

Motor pulsates or surges
under load

Motor does not reverse

1. MAX SPD setting is

too low.

2. Nominal input voltage

may be too low for
motor

3. Motor is overloaded.

1. Motor “bouncing” in

and out of torque limit.

1. Defective DIRECTION

switch connection.

2. Reversing circuit not

working properly.

Problem

Possible

Cause

Suggested

Solution

Advertising