39

Operation

Startup

1. Verify that no conductive material is present on the PCB.

2. Verify that the correct voltage is connected to the inputs

before applying power. DO NOT CONNECT 230 VAC
line voltage to a 115 VAC drive.
Applying power in this
manner will damage the motor and drive.

3. Set the speed adjust potentiometer to zero (full CCW).

4. Set the DIRECTION switch (if installed) to the desired

direction. If no switch is installed, add or remove a
jumper across the (D) and (E1) terminals, as required.

5. Set the ENABLE/DISABLE switch (if installed) to

ENABLE, or short the ENABLE (E2) and (E1) terminals
on TB501.

6. Apply 115 or 230 VAC, 50/60 Hz, single-phase power to

the drive. The green POWER LED will come on after an
initial delay of 1 - 2 seconds. If the POWER LED does
not light, check the external line fuses to ensure that
they are properly installed and not blown.

Warning

DO NOT change jumper settings with power applied.
Ensure that jumper settings are compatible with the
motor being controlled.

Before applying power, verify that no conductive
material is present on the printed circuit board.

ƽ