Application Notes

Independent adjustable speeds with DIR switch

Replace the speed adjust potentiometer with two single-
pole multi-position switches, and two or more
potentiometers in parallel, with a total parallel resistance of
10K ohms. Figure 25 shows the connection of two
independent speed adjust potentiometers that can be
mounted at two separate operating stations.

E2

E1

S1

S2

D (DIRECTION)

S3

FORWARD

REVERSE

TB501

REVERSE

SPEED

FORWARD

SPEED

20K OHM

20K OHM

Figure 25. Independent Adjustable Speeds