33

Installation

Signal and Optional Switch Connections

All signal and switch connections are made at TB501.
Terminal block orientation and terminal names are identical
for all FHP series drives. Use 20 - 24 AWG wire for speed
adjust potentiometer and switch connections.

ENABLE/DISABLE switch

Connect a single-pole, single-throw ENABLE/DISABLE
switch between the ENABLE (E2) and COMMON (E1)
terminals as shown. Open the switch to disable the drive
and coast to a stop. Close the switch to accelerate to set
speed at a rate controlled by the ACCEL trimpot.

E2

E1 (COMMON)

S1

S2

D

S3

ENABLE/DISABLE SWITCH

OPEN TO DISABLE

TB501

Figure 20. Enable / Disable Switch connections to TB501