LEESON FHP Series Chassis Mount Variable Speed Drives User Manual

Page 57

Advertising
background image

47

Calibration

TORQUE LIMIT (TQ LIMIT)

1. With no power applied to the drive, connect a (true

RMS) ammeter in series with one of the motor leads.

2. Set the TQ LIMIT trimpot to full CCW.

3. Carefully lock the motor shaft. Ensure that the motor is

firmly mounted.

4. Apply line power. The motor should be stopped.

5. Set the speed adjust potentiometer or reference signal

to maximum speed. The motor should remain stopped.

6. Slowly rotate the TQ LIMIT trimpot clockwise (CW) until

the ammeter reads 120% of maximum motor current.

7. Set the speed adjust potentiometer or reference signal

to zero speed.

8. Remove power from the drive.

9. Remove the lock from the motor shaft.

10. Remove the ammeter in series with the motor lead.

Warning

Although the TQ LIMIT trimpot can be set up to 150%
of the drive nameplate rating, continuous operation
beyond the drive nameplate rating may cause
damage to the motor and/or drive.

ƽ

Advertising