LEESON FHP Series Chassis Mount Variable Speed Drives User Manual

Page 27

Advertising
background image

17

Installation

Wiring

• Use 20 – 24 AWG wire for speed adjust potentiometer

wiring. Use 14 – 16 AWG wire for AC line (L1, L2) and
motor (U,V and W) wiring.

Warning

DO NOT install, rewire, or remove this control with
input power applied.
Failure to heed this warning
may result in fire, explosion, or serious injury.

Circuit potentials are at 115 or 230 VAC above ground.
To prevent the risk of injury or fatality, avoid direct
contact with the printed circuit board or with circuit
elements.

Do not disconnect any of the motor leads from the
drive unless power is removed. Opening any one
motor lead may destroy the drive.

ƽ

Advertising