58

Troubleshooting

TQ LIMIT LED

The yellow TQ LIMIT LED is on when the drive output
current exceeds the threshold set by the TQ LIMIT trimpot.
When the TQ LIMIT LED turns on, shut down the motor and
drive by disabling or removing power. Check the motor to
make sure it is not jammed or overloaded. The TQ LIMIT
trimpot may need to be recalibrated. See the Calibration
section (page 47) for information on calibrating the TQ
LIMIT trimpot.

IC502

J501

JMP501

J5
02

J

5

03

L1

L2

MAX

TQ LIMIT

ACCEL

DECEL

TB501

AC

AC

-

POWER

FAULT

TQ

V

U

W

POWER

FAULT

TQ

MAX

C510

Figure 29. FHP Series diagnostic LED locations

Advertising