Pattern/Event Trigger Mode
In Pattern/Event Trigger mode, the Analyzer triggers whenever any of the patterns
selected for triggering occurs (an OR condition).
In Pattern/Event/InFusion mode, the ana‐
lyzer can be triggered by an InFusion event that has the Analyzer Trigger action (see Analyzer Trig‐
ger in
Table 4.4 on page 291
).
The procedure for selecting trigger parameters is identical to
that for selecting capture parameters. All items selected for triggering appear in the
Project Overview pane.
To define patterns for triggering, check the Pattern button in the Trigger dialog.
Figure 2.117: Select Patterns for Trigger
The Patterns Library window displays the following trigger pattern categories (for details
on each of the trigger pattern refer to
“Defining Patterns” on page 43
Timers/External
Timer