BEES

BEGINNING ENDING EDGE SHIFT

Description

BEES

provides a measurement of both the beginning and ending edge shift for a subject n pit

(space) preceded and followed by a specified space (pit). (See BES and EES.) The
measurement is calculated between the points where the data and clock signals cross selected
voltage thresholds. The clock period T can be entered by the user, or measured from a user
supplied clock signal, as described below.

The value calculated depends on the clock and data edges selected, as shown in the table below.
The Data Slope menu selects the polarity of the subject n pit/space. If Pos (positive) is selected,
the measurement is performed from the beginning and ending edges of positive polarity pits and
is preceded and followed by a space of the specified width. If Neg (negative) is selected, the
measurement is performed from the edges of negative polarity spaces and is preceded and
followed by a pit of the specified width.

DATA SLOPE

CLOCK

EDGE

Pos

Neg

Positive

times between edges of
positive polarity subject
pit and nearest positive
clock edge

times between edges of
negative polarity
subject space and
nearest positive clock
edge

Negative

times between edges of
positive polarity subject
pit and nearest
negative clock edge

times between edges of
negative polarity
subject space and
nearest negative clock
edge

Near

times between edges of
positive polarity subject
pit and nearest clock
edge

times between edges of
negative polarity
subject space and
nearest clock edge

Advertising