91

The 3T timing jitter is calculated by taking the standard deviation of the difference between each
width and the 3T mean. This is 3.214 ns, normalized by:

Timj

T

3

3 214

100%

2315

1 389%

=

=

.

.

.

The 4T timing jitter cannot be calculated because there is only one value (at least two values are
required).

The 5T timing jitter is +6.109%.

The overall timing jitter is calculated using a weighting formula, which results in the standard
deviation of the mean centered distributions. In this example, it is calculated as:

(

)

(

)

(

)

Timj

overall

=

⋅ − +

⋅ −

+ −

=

1 389

3 1

6109

2 1

3 2 1

3 208%

2