Table 2. Functional Descriptions of DigiTMR Controls and Indicators

Item

Number

Panel Markings

Functional Description

1

RS-232C

9-pin serial computer interface

2

CONTACT INPUT

16-pin female connector for the 3 contact channels.

3

300V MAX

V1 and V2

3-pin connectors. Each input is a voltage detector for the timing voltages of the
trip or close coil switching during the active period. Voltage detection levels
range from 30 to 300 Vdc or peak.

4

300V MAX

TRIGGER

3-pin connector triggers timing functions. Voltage levels ranging from 30 to 300
Vac, dc or peak.

5

CT

AC current sensor input channel.

6

TRAVEL

TRANSDUCER

16-pin male connector. Travel encoder input used for contact motion data.

7

100-120Vac, 2A,

50-60Hz

Fuse: 250Vac, 3A

Fast-Blow

3-wire power plug. 3 Ampere, AC fuses. The ON/OFF switch is a 2-pole rocker.

8

GROUND

Safety ground terminal. 5/16-18 thread stud with wing nut.

9

INITIATE

4-pin connector used for the switching circuit for operating the circuit breaker
under test.

10

CLOSE, OPEN

250V, 5A

SLOW-BLOW

Close circuit fuse: 5 Ampere, 250V, Slow-Blow.

Open circuit fuse: 5 Ampere, 250V, Slow-Blow.

11

“PUSH” TO

ARM

Spring-loaded, pushbutton switch. Press and hold to complete the Trip or Close
circuits for breaker tests.

12

None

Thermal printer. Microprocessor controlled printer that uses specially treated,
4.5-inch wide thermal paper.

13

None

Membrane keypad, 10 alpha-numeric keys and 6 function keys (START,
STOP, CLEAR, ENTER, and CONTRAST/PAPER positioning UP and DOWN)

14

None

Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight and
low-light levels