0 pre-test setup – Vanguard DigiTMR User Manual

Page 15

Advertising
background image

REV 3 DIGITMR USER’S MANUAL

10

2.0 PRE-TEST

SETUP

2.1 Operating

Voltages

The DigiTMR’s operating voltage is preset at the factory and is selectable between 100-120 Vac,
50/60 Hz or 200-240 Vac, 50/60 Hz. To set the proper operating voltage, the voltage selection
jumper must be configured properly as shown in Table 3. The initiate relay with the correct
operating voltage
is also required. The jumper connector is shown in Figure 2 and is marked as
“JP3/VOLT SEL” on the circuit board.

Table 3. Voltage Selection Jumper Settings

Voltage Selection

PINS

Relay Part Number

100 – 120 Vac

1 & 2, 3 &4

HE2aN-Q-AC120V

200 – 240 Vac

2 & 3

HE2aN-Q-AC-240V

Figure 2. Voltage Selection Jumper Settings and Initiate Relay

2.2

Main Power Fuse

The DigiTMR uses an AC input module containing the AC receptacle, power switch, and
protective fuses. The fuses are 3-Ampere, 20mm, 250Vac, fast-blow types. The OPEN and
CLOSE initiate uses 5-Ampere, 3AG, 250Vac, slow-blow type fuses.

2.3

LCD Screen Contrast Control

To increase the LCD screen contrast, press and hold the

[PAPER Contrast]

key for two

seconds.

To decrease the LCD screen contrast, press and hold the

[PAPER Contrast]

key for two

seconds.