8. PARAMETER LISTS

T0801-2.EPS

Write

Mode

Explanation

Factory

Default

Relative

Index

Parameter Name

Index

Used to select resource block options defined in FEATURES.

Identifies the block execution methods available for this resource.
bit0: Scheduled
bit1: Event driven
bit2: Manufacturer specified

Used to select the block execution method for this resource.

Time duration of the shortest cycle interval of which the resource
is capable.

Available configuration memory in the empty resource. To be
checked before attempting a download.

Interval between writing copies of nonvolatile parameters to
non-volatile memory. Zero means never.

Percent of memory available for further configulation. AXF has
zero which means a preconfigured resource.

Percent of the block processing time that is free to process
additional blocks. AXF does not support this.

Time duration at which to give up on computer writes to function
block Rcas locations. Supported only with PID function.

Time duration at which to give up on computer writes to function
block ROut locations. Supported only with PID function.

Condition set by loss of communication to an output block,
failure promoted to an output block or a physical contact.
When fail-safe condition is set, then output function blocks will
perform their FSAFE actions.

Allows the fail-safe condition to be manually initiated by selecting
Set.

Writing a Clear to this parameter will clear the device fail-safe
state if the field condition, if any, has cleared.

Maximum number of unconfirmed notify messages possible.

Maximum number of unconfirmed alert notify messages allowed.

The minimum time between retries of alert reports.

If set, no writes from anywhere are allowed, except to clear
WRITE_LOCK. Block imputs will continue to be updated.

This alert generated by any change to the static data.

The block alarm is used for all configuration, hardware,
connection failure or system problems in the block. The cause of
the alert is entered in the subcode field. The first alert to become
active will set the Active status in the Status attribute. As soon
as the Unreported status is cleared by the alert reporting task,
another block alert may be reported without clearing the Active
status, if the subcode has changed.

The current alert status, unacknowledged states, unreported
states, and disabled states of the alarms associated with the
function block.

Selection of whether alarms associated with the block will be
automatically acknowledged.

Priority of the alarm generated by clearing the write lock.

This alert is generated if the write lock parameter is cleared.

Version number of interoperability test by Fieldbus Foundation
applied to AXF.

AXF software revision number.

Yokogawa internal use.

Software switch for simulation function.

19 1019

CYCLE_TYPE

0x0001

-

21 1021

MIN_CYCLE_T

3200

-

22 1022

MEMORY_SIZE

0

-

23 1023

NV_CYCLE_T

0

-

24 1024

FREE_SPACE

0

-

25 1025

FREE_TIME

0

-

26 1026

SHED_RCAS

640000(20S)

Auto

27 1027

SHED_ROUT

640000(20S)

Auto

28 1028

FAULT_STATE

1

-

31 1031

MAX_NOTIFY

3

-

32 1032

LIM_NOTIFY

3

Auto

33 1033

CONFIRM_TIME

640000(20S)

Auto

34 1034

WRITE_LOCK

1(Not

Locked) Auto

35 1035

UPDATE_EVT

1(Acknowledged) Auto

36 1036

BLOCK_ALM

1(Acknowledged) Auto

40 1040

WRITE_ALM

1(Acknowledged) -

41 1041

ITK_VER

-

37 1037

ALARM_SUM

0

-

38 1038

ACK_OPTION

0xffff

Auto

39 1039

WRITE_PRI

0

Auto

42 1042

SOFT_REV

-

43 1043

SOFT_DESC

-

44 1044

SIM_ENABLE_MSG

Spaces

Auto

29 1029

SET_FSTATE

1

-

30 1030

CLR_FSTATE

1

-

20 1020

CYCLE_SEL

0x0001

Auto

18 1018

FEATURE_SEL

0x000a

Auto