8. PARAMETER LISTS

8.4

Dl Function Block

T0804-1.EPS

Write

Mode

Explanation

Factory

Default

Relative

Index

Parameter Name

Index

DI1

Index

DI2

Information on this block such as Block Tag, DD Revision,
Execution Time etc.

The revision level of the static data of the DI block. The
value of this parameter is incremented each time a static
parameter value is changed. Valid range is 0 to 65535.

The user description of the intended application of the block

Used by an upper-level system to identify grouping of the
block. Not checked or processed by the block. Valid range
is 0 to 65535.

The identification number of the plant unit. This information
may be used in the host for sorting alarms, etc.

The actual, target, permitted and normal modes of the block.

Indicates the error statuses related to the block itself.

The primary discrete value (or process value) for execution
of the block's functions.

Indicates the value and status of block's output.

Allows use of values manually set instead of the limit switch
input from the transducer block. When Disable is set for
this value, the block reflects the actual input value and
status. 1: Disabled, 2: Active

Not used in AXF.

Not used in AXF.

Option to control access from the host computer and local
control panel to tuning and alarm parameters. Before write
access to a parameter, set the GRANT bit in this parameter
to have the operation right to be granted. Then after write
access, check the DENY bit in this parameter. If the write
access is successfully, it is not ON.

Sets the block input/output options. The AXF supports only
0: Invert (LSB).

Defines block actions depending on block status conditions.
For DI blocks of the AXF, 3: Propagate fault Forward,
8: Uncertain if Man mode are supported.

The channel number of the transducer block's logical
hardware channel connected to this block. Valid range is
2: LIMSW_1, 3: LIMSW_2, 4: SWITCH_1, 5: SWITCH_2

Sets the time constant of damping for PV_D.

The status of the limit switch signal transferred from the
transducer block.

1 6001

6101

ST_REV

0

0 6000

6100

Block

Header

O/S

3 6003

6103

STRATEGY

1

Auto

4 6004

6104

ALERT_KEY

1

Auto

5 6005

6105

MODE_BLK

6 6006

6106

BLOCK_ERR

7 6007

6107

PV_D

8 6008

6108

OUT_D

9 6009

6109

SIMULATE_D

Auto

10 6010 6110

XD_STATE

0

13 6013 6113

IO_OPTS

0x0000 O/S

14 6014 6114

STATUS_OPTS

0x0000 O/S

15 6015 6115

CHANNEL

O/S

16 6016 6116

PV_FTIME

0

Auto

17 6017 6117

FIELD_VAL_D

Shows the content of an update event (a change to the
setpoint) upon occurrence.

18 6018 6118

UPDATE_EVT

-

Shows the contents of a block alarm upon occurrence

19 6019 6119

BLOCK_ALM

-

Indicates the current alarm statuses.

20 6020 6120

ALARM_SUM

0x0000

Selects whether alarms associated with the block will be
automatically acknowledged.

21 6021 6121

ACK_OPTION

0xFFFF

Sets the alarm priority level.

22 6022 6122

DISC_PRI

0

Indicates the status of the input for the discrete alarm.

23 6023 6123

DISC_LIM

0

Indicates the status of the related to the discrete alarm.

24 6024 6124

DISC_ALM

11 6011 6111

OUT_STATE

0

12 6012 6112

GRANT_DENY

Auto

2 6002

6102

TAG_DESC

spaces Auto

DI1: TAG="DI1"
DI2: TAG="DI2"

DI1: 2
DI2: 3