A2.7 list of integrator block parameters, A-15 – Yokogawa AXFA14G/C User Manual

Page 74

Advertising
background image

IM 01E20F02-01E

A-15

APPENDIX 2. INTEGRATOR (IT) BLOCK

A2.7 List of Integrator Block Parameters

TA0206-1.EPS

Index

Parameter

Name

Initial
Value

Write

Mode

Definition

OUT

IN_1

IN_2

SSP

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

0

2 2 2 2

1 2 3 4

2

1

4

4

2

2

4

4

5

5

2

11

2

5

5

5

5

2

2

2

2

1

1

4

4

4

2

2

2

2

2

2

4

4

4

4

4

1

2

Spaces

1

1

0

1000000.0

1000000.0

0.0

m3(1034)

0

0

0

0.0

0.0

0

0

sec(1)

sec(1)

1.0

1.0

1.0

0

0

0

0.0

0.0

0.0

0.0

UP_AUTO

(1)

0

؋0004

Block Tag

=o/s

MAN

OS

MAN

MAN

MAN

MAN

MAN

Auto

Auto

Auto

Auto

Auto

Auto

Auto

Auto

Auto

View

BLOCK_HEADER

ST_REV

TAG_DESC

STRATEGY

ALERT_KEY

MODE_BLK

BLOCK_ERR

TOTAL_SP

OUT_RANGE

GRANT_DENY

STATUS_OPTS

OUT_TRIP

OUT_PTRIP

TIME_UNIT1

TIME_UNIT2

UNIT_CONV

PULSE_VAL1

PULSE_VAL2

REV_FLOW1

REV_FLOW2

RESET_IN

STOTAL

RTOTAL

SRTOTAL

INTEG_TYPE

INTEG_OPTS

Information relating to this function block, such as block tag,
DD revision, execution time
The revision level of the set parameters associated with the Integrator block

Stores comments describing tag information.

The strategy field is used by a high-level system to identify the function block.

Key information used to identify the location at which an alert occurred

Integrator block mode. O/S, MAN, and AUTO are supported.

Indicates the active error conditions associated with the function block in bit strings.

The setpoint of an integrated value or a start value for counting down

The block output

Set scaling for output display. This does not affect operation of the function block.
It is used for making memos.

The parameter for checking if various operations have been executed

Allows you to select a status-related option.
The Integrator block uses "Uncertain if Man mode" only.

Inputs flow (Rate, Accum) signals from the AI block or PI block.

An output parameter informing the user that the integrated value has exceeded the setpoint

An output parameter informing the user that the integrated value is reaching the setpoint

Set the time unit of the rate (kg/s, lb/min, kg/h ... etc.) of the
corresponding IN.

Set the factor for converting the number of pulses for the corresponding
IN into an appropriate engineering unit.

Selector switch used to specify the fluid flow direction
(forward/reverse) with respect to the corresponding IN

The parameter that receives a reset request from an external block to reset the integrated values

Indicates the snapshot of OUT just before a reset.

Indicates the integrated value of the absolute values of the increments if the input status is "Bad."

Indicates the snapshot of RTOTAL just before a reset.

Indicates the snapshot of TOTAL_SP just before a reset.

Integration Type Setting

Specifies an integration optional function.

Value

Name

Description

1

UP_AUTO

Counts up and is automatically reset when TOTAL_SP is reached.

2

UP_DEM

Counts up and is reset as demanded.

3

DN_AUTO

Counts down and is automatically reset when "0" is reached.

4

DN_DEM

Counts down and is reset as demanded.

5

PERIODIC

Counts up and is reset at periods specified in CLOCK_PER.

6

DEMAND

Counts up and is reset as demanded.

7

PER&DEM

Reset periodically or as demanded.

bit

Option Name

Description

0

Input 1 accumulate

Selects Rate or Accum input of IN_1.

1

Input 2 accumulate

Selects Rate or Accum input of IN_2.

2

Flow forward

Integrates forward flow (interprets reverse flow as zero).*

3

Flow reverse

Integrates reverse flow (interprets forward flow as zero).*

4

Use uncertain

Uses an input value of IN_1 or IN_2 whose status is "Uncertain"
regarding it as a value of "Good."

7

Add zero if bad

Interprets an increment as zero if the status of the increment is "Bad."

9

Generate reset event

Generates an alert event at reset.

* If both forward and reverse flows are enabled or disabled, both forward and reverse flows are integrated.

10

ف15 Reserved

5

Use bad

Uses an input value of IN_1 or IN_2 whose status is "Bad" regarding
it as a value of "Good."

6

Carry

Carries over an excess exceeding the threshold at reset to the next
integration. (Note that this does not apply to UP_AUTO or DN_AUTO.)

8

Confirm reset

After a reset, rejects the next reset until "Confirm" is set to
RESET_CONFIRM.

Specify the unit conversion factor for standardizing the unit of IN_2 into that of IN_1.

IT1:TAG="IT1"
IT2:TAG="IT2"