2. HANDLING PRECAUTIONS

2.3 Storage Precautions

If the instrument is to be stored for a long period of
time after delivery, observe the following points.

᭹ The instrument should be stored in its original

packing condition in the storage location.

᭹ Select a storage location that fulfils the following

conditions:

• A place where it will not be exposed to rain or

water

• A place subject to minimal vibrations or shocks
• Temperature and humidity levels should be as

follows:

Temperature: -30 to 70

°C

Humidity: 5 to 80% RH (no condensation)

The preferred ambient temperature and
humidity levels are 25

°C and approximately

65% RH.

᭹ If the AXF magnetic flowmeter is transferred to the

installation site and stored without being installed,
its performance may be impaired due to the infiltra-
tion of rainwater and so forth. Be sure to install and
wire the AXF magnetic flowmeter as soon as
possible after transferring it to the installation
location.

2.4 Installation Location

Precautions

Select the installation location with consideration to the
following items to ensure long-term stable operation of
the instrument.

᭿ Ambient Temperature:

Avoid installing the instrument in locations with
constantly fluctuating temperatures. If the location is
subject to radiant heat from the plant, provide heat
insulation or improve ventilation.

᭿ Atmospheric Condition:

Avoid installing the instrument in a corrosive
atmosphere. In situations where this is unavoidable,
consider ways to improve ventilation and to prevent
rainwater from entering and being retained in the
conduit pipes.

᭿ Vibrations or Shocks:

Avoid installing the instrument in a place subject to
shocks or vibrations.

᭿ Explosion protected type:

Explosion protect types can be installed in hazard-
ous areas according to the types of gases for which
they are certified. See the description in Chapter 8
“EXPLOSION PROTECTED TYPE INSTRU-
MENT” and “INSTALLATION AND OPERATING
PRECAUTIONS FOR TIIS FLAMEPROOF
EQUIPMENT” in this user's manual.