7-1

7. PED (PRESSURE EQUIPMENT DIRECTIVE)

7. PED

(PRESSURE EQUIPMENT DIRECTIVE)

This chapter describes further requirements and notices
concerning the PED (Pressure Equipment Directive).
The description in this chapter is prior to other descrip-
tion in this User’s Manual.

(1) Technical Data

Module: H
Type of Equipment: Piping
Type of Fluid: Liquids and gas
Group of Fluid: 1 and 2

General-purpose Use / Submersible Type / Explosion
Proof Type

MODEL

DN

(mm) (*1)

PS

(MPa) (*1)

PS DN

(MPa · mm)

CATEGORY(*2)

AXF002G/C

2.5

4

10

Article 3, (*3)
paragraph 3

AXF005G/C

5

4

20

Article 3, (*3)
paragraph 3

AXF010G/C

10

4

40

Article 3, (*3)
paragraph 3

AXF015G/W/C

15

4

60

Article 3, (*3)
paragraph 3

AXF025G/W/C

25

4

100

Article 3, (*3)
paragraph 3

AXF032G/W/C

AXF040G/W/C

AXF050G/W/C

AXF065G/W/C

AXF080G/W/C

AXF100G/W/C

AXF125G/W/C

AXF150G/W/C

AXF200G/W/C

AXF250G/W/C

AXF300G/W/C

AXF350G/W/C

AXF400G/W/C

32

40

50

65

80

100

125

150

200

250

300

350

400

4

4

4

2

2

2

2

2

2

2

2

1

1

128

160

200

130

160

200

250

300

400

500

600

350

400

II

II

II

II

II

II

II

II

III

III

III

II

III

T0701.EPS

Sanitary Type

T0702.EPS

MODEL

DN

(mm) (*1)

PS

(MPa) (*1)

PS D

(MPa · mm)

CATEGORY (*2)

AXF015H

15

1

15

Article 3, (*3)
paragraph 3

AXF025H

25

1

25

Article 3, (*3)
paragraph 3

AXF032H

AXF040H

AXF050H

AXF065H

AXF080H

AXF100H

AXF125H

32

40

50

65

80

100

125

1

1

1

1

1

1

1

32

40

50

65

80

100

125

I

I

I

I

I

I

II

Note : The sizes of 500 to 2600 mm (20 to 104 in.) are not

attached CE marking of PED.

*1: PS: Maximum allowable pressure for Flowtube

DN: Nominal size

*2: For details, see “Table 6 covered by ANNEX II of EC

Directive on Pressure Equipment Directive 97/23/EC.”

*3: AXF002G/C to AXF025G/W/C, AXF015H and AXF025H

are outside the scope of CE marking of PED.

(2) Installation

WARNING

• Tighten the bolts of the piping joints according

to the prescribed torque values.

• Take measures to protect the flowmeters from

forces caused by vibration channeled through
the piping.

(3) Operation

WARNING

• The instrument should be operated with the

temperature and pressure of the fluid under
normal operating conditions.

• The ambient temperature should be that of

normal operating conditions.

• Take measures to prevent excessive pressure

such as water hammer, etc. To avoid water
hammer prevent the pressure from exceeding
the PS (maximum allowable pressure) by
setting the system’s safety valves, etc. appro-
priately.

• Should external fire occur, take safety mea-

sures at the device itself or system-wide
prevent it having an effect on the flowmeters.

• Avoid using fluids exceeding the corrosion

proof limitations of the lining and electrodes.

• Take measures not to abrade the metal pipe,

and avoid abrading the lining by using fluids
such as slurry and sand are contained.

Advertising