6. OUTLINE

Size of AXF Flowtubes: Replacement model for earlier ADMAG or ADMAG AE (Lay length code 2)

Use

Process Connection

Lining

Remote Flowtube

Integral Flowmeter

High Grade

Accuracy 0.2% of

Rate

Enhanced Dual Frequency

Excitation

(Optional code HF1,HF2)

Replaceable Electrode

(Electrode structure code 2)

PFA

2.5 (0.1), 5 (0.2), 10 (0.4), 15 (0.5),
25 (1.0), 40 (1.5), 50 (2.0), 80 (3.0),
100 (4.0), 150 (6.0), 200 (8.0)

25 (1.0), 40 (1.5), 50 (2.0),
80 (3.0), 100 (4.0),
150 (6.0), 200 (8.0)

Polyurethane

rubber

25 (1.0), 40 (1.5), 50 (2.0), 80 (3.0),
100(4.0), 150 (6.0), 200(8.0)

25 (1.0), 40(1.5), 50 (2.0),
80(3.0), 100 (4.0),
150 (6.0), 200 (8.0)

150 (6.0), 200 (8.0), 250 (10)

150 (6.0), 200 (8.0), 250 (10)

PFA

150 (6.0), 200 (8.0), 250 (10)

General-

purpose use

Wafer (*6)

Flange (*7)

Unit: mm (in.)

Polyurethane

rubber

150 (6.0), 200 (8.0)

150 (6.0), 200 (8.0)

150 (6.0), 200 (8.0), 250 (10)

PFA

15 (0.5), 25 (1.0),
40 (1.5), 50 (2.0),
80 (3.0), 100 (4.0),
150 (6.0), 200 (8.0)

25 (1.0), 40 (1.5),
50 (2.0), 80 (3.0), 100 (4.0),
150 (6.0), 200 (8.0)

Polyurethane

rubber

25 (1.0), 40 (1.5), 50 (2.0),
80 (3.0), 100 (4.0),
150 (6.0), 200 (8.0)

Wafer (*6)

Submersible

Type

25 (1.0), 40 (1.5),
50 (2.0), 80 (3.0),
100 (4.0), 150 (6.0),
200 (8.0)

Flange (*7)

PFA

Polyurethane

rubber

150 (6.0), 200 (8.0),
250(10)

150 (6.0), 200 (8.0),
250 (10)

150 (6.0), 200 (8.0)

150 (6.0), 200 (8.0)

*6: ADMAG lay length dimensions for wafer type of 250 mm (10 in.), and 300 mm (12 in.) are the same as those for AXF Standard.

And, in case of “platinum-iridium (grounding ring code P) or tantalum (grounding ring code T) or None (grounding ring code N)” in wafer type of 2.5 mm (0.1 in.)

to 15 mm (0.5 in.), the lay lengths of Replacement model are the same as those for AXF Standard.

*7: ADMAG lay length dimensions for flange type of 15 mm (0.5 in.) to 100 mm (4.0 in.), or 300 mm (12 in.) to 2600 mm (104 in.) are the same as those for AXF

Standard. However, in case of platinum-iridium (grounding ring code P) or tantalum (grounding ring code T) or None (grounding ring code N) in flange type of 15
mm (0.5 in.) to 100 mm (4.0 in.), the lay length of AXF Standard are longer by approx. 4mm (0.16 in) than those of earlier ADMAG or ADMAG AE.

T22.EPS

PFA

2.5 (0.1), 5 (0.2), 10 (0.4), 15 (0.5),
25 (1.0), 40 (1.5), 50 (2.0), 80 (3.0),
100 (4.0), 150 (6.0), 200 (8.0)

25 (1.0), 40 (1.5), 50 (2.0),
80 (3.0), 100 (4.0),
150 (6.0), 200 (8.0)

Explosion

proof Type

Wafer (*6)

150 (6.0), 200 (8.0), 250 (10)

PFA

Flange (*7)

150 (6.0), 200 (8.0)

· Housing, Flange (Flange type only), Terminal Box

and Cover (Remote Flowtube):

Corrosion-resistant coating

Coating color; Mint green (Munsell 5.6 BG 3.3/2.9

or its equivalent)

Sanitary Type:

Size 15 to 125 mm (0.5 to 5.0 in.):

· Housing: No coating (Stainless steel surface)
· Adapter : No coating (Stainless steel surface)
· Terminal Box and Cover (Remote Flowtube):

Corrosion-resistant coating

Coating color; Mint green (Munsell 5.6 BG 3.3/2.9

or its equivalent)

Protection:

General-Purpose Use/Sanitary Type/TIIS Flameproof
Type:

IP66, IP67

Explosion proof type except TIIS:

In case of explosion proof type except TIIS, refer to
description of “Enclosure” in “HAZARDOUS AREA
CLASSIFICATION”.

Submersible Type (only for Remote Flowtube):

IP68 (Conforms to continuous immersion under the
following test condition)
Test Condition: 50 m below the surface of the water,

equivalent to 0.5 MPa hydraulic
pressure, for one month.
Cable should be protected at customer
site.

Coating:

General-Purpose Use/Explosion proof Type:

Size 2.5 to 125 mm (0.1 to 5.0 in.) (Wafer type),
Size 2.5 to 125 mm (0.1 to 5.0 in.) (Process connection
code B or D of flange type):

· Housing: No coating (Stainless steel surface)
· Flange (Flange type only) : No coating (Stainless

steel surface)

· Terminal Box and Cover (Remote Flowtube):

Corrosion-resistant coating

Coating color; Mint green (Munsell 5.6 BG 3.3/2.9

or its equivalent)

Size 150 to 300 mm (6.0 to 12 in.) (Wafer type),
Size 150 to 400 mm (6.0 to 16 in.) (Process connection
code B of flange type),
Size 50 to 2600 mm (2.0 to 104 in.) (Process connection
code C of flange type):