Revised Item

6th

Oct. 2005

3-22 to 3-24

Added the "Confirmation of adapter mounting screw"

5-1

(7)

Added the sentence.

5-5

Added the note of installation

6-7

Added the note of permeable fluids to the grounding ring/grounding
electrode.

6-12

Added the "IECEx" to the hazardous area classification.

6-14

Added the "SF2 (IECEx)" to the withstand voltage.

6-21 to 6-27

Changed the note for wetted parts material.

6-28

MU

Changed description of the "mass unit setting (MU)".

6-29

PM

Changed the value of the mirror finished PFA lining (PM).
Changed from "Ra 0.05 to 0.15

µm" to "Size 15 to 200 mm :

Ra 0.05 to 0.15

µm, Size 250 to 400 mm : Ra 0.05 to 0.25 µm"

6-31

SF2

Added the "IECEx Certification (SF2)" to the optional specifications.

6-39

Corrected the "Weight kg (lb)" of BD4.

6-40

Corrected the "Weight kg (lb)" of BJ1/CJ1, BJ2/CJ2 and BG1/CG1.

6-48

Corrected the "Inner diameter of grounding ring (ød)" of size 250mm.

8-7 to 8-8

8.5

Added the "IECEx".

7th

June 2006

1-1

Added the postscript about F

OUNDATION

Fieldbus protocol type.

3-11

Table 3.3.7 Changed the Torque Value.

3-12

Table 3.3.8 Changed the Torque Value.

3-13

Table 3.3.9 Changed the Torque Value.

3-16

Table 3.3.14 Changed the Torque Value.

3-17

Table 3.3.15 Changed the Torque Value.

3-18

Table 3.3.16 Changed the Torque Value.

3-22

5)

Added the sentence.

3-23

5)

Added the sentence.

3-24

5)

Added the sentence.
Changed the Figure 3.3.10.

4-3

(2)

Added the postscript about F

OUNDATION

Fieldbus protocol type.

4-6

(6)

Added the postscript about F

OUNDATION

Fieldbus protocol type.

4-13

1), 2)

Added the “IECEx”.

5-5

5.3

Added the CAUTION.
Changed the Figure 5.3.1.

5-8

5.4.3

Added the postscript about F

OUNDATION

Fieldbus protocol type.

5-9

5.5.1

Added the postscript about F

OUNDATION

Fieldbus protocol type.

5-10

5.5.2

Added the postscript about F

OUNDATION

Fieldbus protocol type.

6-1, 14, 20, 28

Added the postscript about F

OUNDATION

Fieldbus protocol type.

6-7

Corrected from “SPCC” to “SS400” in Housing of size 500 mm to
2600 mm

6-17 to 20

Corrected the value of Pressure on figure.

6-21 to 6-23

Added the “-F” (F

OUNDATION

Fieldbus protocol).

6-25 to 6-27

Added the “-F” (F

OUNDATION

Fieldbus protocol).

6-34 to 6-48

Added the postscript about F

OUNDATION

Fieldbus protocol type.