4-3

4. WIRING

(3) Conduit Wiring

When wiring the conduits, pass the conduit through the
wiring connection port, and utilize the waterproof
gland to prevent water from flowing in. Place the
conduit pipe on an angle as shown in Figure 4.1.4.
Install a drain valve at the low end of the vertical pipe,
and open the valve regularly.

F0404.EPS

Drain valve

Figure 4.1.4

Conduit Wiring

4.1.4

Wiring Connections

(1) Removing Cover

Loosen cover locking screw 2 clockwise using a
hexagonal wrench (nominal size 3) to unlock the cover.
(Upon shipment from the manufacturing plant, the
cover is unlocked.) Hold the flowmeter with your hand
and remove the cover by turning it in the direction of
the arrow as shown below.

F0405.EPS

Cover locking
screws

1

2

Figure 4.1.5

Removing the Terminal Box Cover

(2) Terminal Configuration

When the cover is removed, the connection terminals
will be visible.

F0406.EPS

+

SUPPLY

DIO

POWE

-

+

/

LN

/

I

-

+

+

-

D

-

Figure 4.1.6

Terminal Configuration

The description of the terminal symbols is shown in
Table 4.1.1.

For F

OUNDATION

Fieldbus protocol, please refer to IM

01E20F02-01E.

For PROFIBUS PA protocol, please refer to IM
01E20F12-01E.

Table 4.1.1 Terminal Symbols

Terminal

Symbols

Functional grounding

Power supply

Current output 4 to 20mA DC

Pulse output/Alarm output/

Status output

Alarm output/Status output

Status input

Protective grounding

(Outside of the terminal)

Description

N/-
L/+
I+
I-
DO+
DO-
DIO+
DIO-

T0401.EPS

(3) Precautions for Wiring of Power Supply

Cables

When connecting to the power supply, observe the
points below. Failure to comply with these warnings
may result in an electric shock or damage to the
instrument.

WARNING

• Ensure that the power supply is OFF in order to

prevent electric shocks.

• Ensure the protective grounding terminal is

grounded before turning the power on.

• Use insulating sleeve crimp terminals (for 4-mm

screws) for the power supply wiring and protec-
tive grounding wiring.

Advertising