3 csa, Csa -5 – Yokogawa ADMAG AXF User Manual

Page 121

Advertising
background image

IM 01E20D01-01E

8-5

8. EXPLOSION PROTECTED TYPE INSTRUMENT

Conduit

Magnetic Flowmeter

Sealing Fitting

HAZARDOUS LOCATIONS

18" (457 mm) Max.

F0802.EPS

Figure 8.2.1 Conduit Wiring

8.3 CSA

(1) Technical Data

*AXF002C – AXF400C
Applicable Standard:

For CSA C22.2 Series;

C22.2 No 0, C22.2 No 0.4, C22.2 No 0.5,
C22.2 No 25, C22.2 No 30, C22.2 No 94,
C22.2 No 157, C22.2 No 1010.1

For CSA E79 Series;

CAN/CSA-E79-0, CAN/CSA-E79-1,
CAN/CSA-E79-7, CAN/CSA-E79-11,
CAN/CSA-E79-18

Certificate: 1481213
Process Sealing Certification:

Dual Seal certified by CSA to the requirements of
ANSI/ISA 12.27.01.
No additional sealing required.
Primary seal failure annunciation;

Deterioration of the flowrate output at nonzero
flow point.
Unstable flowrate output at zero flow point.

(Integral Flowmeter)
For CSA C22. 2 Series

Explosion proof for Class I, Division 1, Groups A,

B, C & D.

Dust-ignition proof for Class II/III, Division 1,

Groups E, F & G.

Intrinsically safe (electrodes) for Class I, Division 1,

Groups A, B, C & D.

“SEAL ALL CONDUITS WITHIN 50 cm OF THE

ENCLOSURE”

“WHEN INSTALLED IN DIV. 2, SEALS NOT

REQUIRED”

Electrode Circuit Um: 250 Vac/dc
Maximum power supply voltage: 250 Vac/130 Vdc
Excitation Circuit: 140V max
Enclosure: Type 4X
Temperature Code:

T27-1.EPS

+70

°C (+158°F)

+85

°C (+185°F)

Temperature

Code

+120

°C (+248°F)

Maximum Process

Temperature

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

T6

Minimum Process

Temperature

T4

T5

T3

+130

°C (+266°F)

Ambient Temp.: –40

°C to +60°C (–40°F to +140°F)

For CSA E79 Series

Flameproof for Zone 1, Ex dme [ia] IIC T6...T3
Intrinsically safe (electrodes), Ex ia IIC T6...T3

Electrode Circuit Um: 250 Vac/dc
Maximum power supply voltage: 250 Vac/130 Vdc
Excitation Circuit: 140V max
Enclosure: IP66, IP67
Temperature Code:

T0807.EPS

+70

°C (+158°F)

+85

°C (+185°F)

Temperature

Code

+120

°C (+248°F)

Maximum Process

Temperature

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

T6

Minimum Process

Temperature

T4

T5

T3

+130

°C (+266°F)

Ambient Temp.: –40

°C to +60°C (–40°F to +140°F)

(Remote Flowtube)
For CSA C22.2 Series

Explosion proof for Class I, Division 1, Groups A,

B, C & D.

Dust-ignition proof for Class II/III, Division 1,

Groups E, F & G.

Intrinsically safe (electrodes) for Class I, Division 1,

Groups A, B, C & D.

“SEAL ALL CONDUITS WITHIN 50 cm OF THE

ENCLOSURE”

“WHEN INSTALLED IN DIV. 2, SEALS NOT

REQUIRED”

Electrode Circuit Um: 250 Vac/dc
Excitation Circuit: 170V max
Enclosure: Type 4X
Temperature Code:

T28-1.EPS

Temperature

Code

Maximum Process

Temperature

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

T6

Minimum Process

Temperature

T4

T5

T3

+70

°C (+158°F)

+85

°C (+185°F)

+120

°C (+248°F)

+150

°C (+302°F)

Ambient Temp.: –40

°C to +60°C (–40°F to +140°F)

For CSA E79 Series

Flameproof for Zone 1, Ex dme [ia] IIC T6...T3
Intrinsically safe (electrodes), Ex ia IIC T6...T3

Electrode Circuit Um: 250 Vac/dc
Excitation Circuit: 170V max
Enclosure: IP66, IP67