3. OPERATION

IM 01C50T01-01E

3-2

Table 3.1 Parameters list

Item

Description

Page

HART

Communicator

Tag number, up to 8 characters

Extension of Tag, up to 8 characters

Up to 16 characters

Up to 32 characters

mm/dd/yy

To describe a serial number of sensor.
0 to 16777215

°

C, K,

°

F,

°

R (Note 1)

Set the calibration range using the keypad.

Value for 4 and 20 mA signal is set with actual input applied.

Adjust the output response speed of the 4 to 20 mA DC.
Enter integer value from 0 to 99 seconds.

Set the % of PV where the damping function is disabled.
When PV exceeds this value, the damping is disabled and
the output follows the PV.

Specify the value to be used as PV from: “Sensor1”,
“Terminal Temperature(Term)” and “Sensor1-Term”. The SV,
TV and 4V can also be specified and monitored from the
HART communicator or Integral Indicator.
The YTA320 variables include above plus: “Sensor2”,
“Sensor2-Term”, “Average” and “Differential temperature”.

When using differential value, select whichever is desired;
Sensor1-Sensor2 or Sensor2-Sensor1.

Specify input type.

Specify the number of wire for RTD or ohm input.

Select a unit from

°

C, K,

°

F, or

°

R. (See note 1). This unit is

automatically referred as a PV, SV, TV or 4V unit when
Sensor1 is mapped.

Enable / disable sensor matching function. When it is set to
“enable”, sensor coefficient parameter can be entered.

Sensors specific co-efficients (by Callender vanDusen or
IEC)

Select a unit from

°

C, K,

°

F, or

°

R. (See note 1). This unit is

automatically referred as a PV, SV, TV or 4V unit when
Terminal Temperature is mapped.

Select CJC function

Specify constant value to be used for CJC function.

Specify input type.

Specify the number of wires.

Select a unit from

°

C, K,

°

F, or

°

R. (See note 1). This unit is

automatically referred as a PV, SV, TV or 4V unit when
Sensor2 is mapped.

Enable/disable sensor matching function. When it is set to
“enable”, sensor coefficient parameter can be set.

Sensors specific co-efficients (by Callender vanDusen or
IEC)

Enables/disables sensor back-up mode.

Shows the back-up status.

Enables the recovery from Sensor2 to sensor1 in back-up
operation.

Tag

Tag Ex

Descriptor

Message

Date

Sensor1(2)
snsr s/n

PV units
(SV,TV,4V)

LRV/URV

Apply values

PV Damp
(SV,TV,4V)

PV damp point

PV is
(SV,TV,4V)

Diff direction
(YTA320 only)

Snsr1 Type

Snsr1 Wire

Snsr1 unit

Snsr1 Match
Enbl

Snsr1 Match
coefs

Term unit

CJC Select

CNST CJC
Temp

Snsr2 Type

Snsr2 Wire

Snsr2 unit

Snsr2 Match
Enbl

Snsr2 Match
coefs

Enbl Snsr Bkup

Bkup state

Bkup Return
Snsr1

Memory

Process Variable

Sensor1
Configuration

Terminal
Temperature

Sensor2
Configuration
(YTA320 only)

Engineering Unit

Range

Damping time
constant

PV damping
holding point

Variable
mapping

Differential
Direciton

Sensor1 type

Sensor1 wire

Sensor1 unit

Sensor matching
function (Note 2)

Terminal Temp.
unit

CJC Function

Sensor2 type

Sensor2 wire

Sensor2 unit

Sensor matching
function (Note 2)

Sensor Back-up
Function

(YTA320 only)

T0301_1.EPS

Note 1:

°

F and

°

R are available only when option code /D2 is specified.

Note 2:

The parameters are available only when option code /CM1 is specified with YTA310/YTA320.

3-11

3-11

3-11

3-11

3-11

3-8

3-9

3-10

3-10

3-10

3-6

3-8

3-5

3-5

3-5

3-17

3-17

3-18

3-18

3-5

3-5

3-5

3-17

3-17

3-16

3-16

3-16