3.2 Menu Tree

1.Device setup

2.PV

3.PV AO

4.PV LRV

5.PV URV

1.Process variables

2.Diag/Service

3.Basic setup

4.Detailed setup

5.Review

1.Variable view

2.Variable setting

3.Max/Min log

1.Variable map

2.Diff direction

3.Unit&Damp

1.PV
2.PV % rnge
3.PV AO
4.SV
5.TV
6.4V
7.Term

1.PV is
2.SV is
3.TV is
4.4V is

1.Status group 1
2.Status group 2
3.Status group 3
4.Status group 4
5.Status group 5
6.Status group 6

1.PV LRV
2.PV URV
3.PV Unit
4.PV LSL
5.PV USL

1.Snsr 1 inp trim

2.Snsr 2 inp trim

1.D/A trim
2.Scaled D/A trim
3.D/A Clr to Default

1.Snsr1
2.Snsr 1 config
3.Snsr 1 inp trim

4.Snsr 1 info.

1.Snsr2
2.Snsr 2 config
3.Snsr 2 inp trim

4.Snsr 2 info.

1.Term
2.Term Unit
3.Term temp Limits
4. CJC Select
5.

CNST CJC Temp

1.Snsr Bkup
2.Bkup State
3. Bkup Return Snsr1

1.AO
2.AO Alrm typ
3.Loop test
4.AO D/A Trim

5.Snsr burnout

1.Poll addr
2.Num req preams
3.Burst mode
4.Burst option

1.Display select

2.Disp Update

1.Universal rev
2.Fld dev rev
3.Software rev

1.PV LRV
2.PV URV
3.PV Unit
4.PV LSL
5.PV USL

1.Snsr2 Type
2.Snsr2 Wire
3.Snsr2 unit
4.Snsr2 Match Enbl

1.PV Unit&Damp

2.SV Unit&Damp

3.TV Unit&Damp

4.4V Unit&Damp

5.Term Unit

1.PV Unit
2.PV Damp
3.PV damp point

1.SV Unit
2.SV Damp

1.TV Unit
2.TV Damp

1.4V Unit
2.4V Damp

1.Snsr1
2.Input Triming Mode
3.Sns1 Trim Act
4.S1 Trim Zero/Gain

1.Snsr2
2.Input Triming Mode
3.Sns2 Trim Act
4.S2 Trim Zero/Gain

1.Snsr1 snsr s/n
2.Snsr1 LSL
3.Snsr1 USL

1.Snsr2 snsr s/n
2.Snsr2 LSL
3.Snsr2 USL

1.Term LSL
2.Term USL

1.Snsr burnout type
2.Snsr burnout val

1.Process Disp
2.%/mA Disp
3.Err-No Disp
4.Bar graph
5.Matrix Disp

1.PV max/min log
2.SV max/min log
3.TV max/min log
4.4V max/min log
5.Term max/min log
6.Max/Min log Clear

1.Status

2.Self test
3.Master test

4.Set waming enbl

1.Apply values

2.Range values

3.Sensor Trim

4.AO D/A Trim

1.Error log view
2.Error log clear

1.Power Check
2.Operate Time

1.PV Unit
2.PV Damp
3.PV damp point

1.Process sensor 1

2.Process sensor 2

3.Term temp sensor

4.Snsr Backup

1.PV % rnge
2.PV LRV
3.PV URV
4.PV Unit&Damp
5.Apply values
6.PV LSL
7.PV USL
8.PV Min span

1.Analog output

2.HART output

3.Meter output

1.Tag
2.Tag Ex
3.Descriptor
4.Message
5.Date
6.Final asmbly num
7.Distributor
8.Model
9.Dev id

Write protect

Revision #’s

1.Snsr1 Type
2.Snsr1 Wire
3.Snsr1 unit
4.Snsr1 Match Enbl

1.Test device

2.Loop test

3.Calibration

4.Error log

5.Power monitoring

Online Menu

(Device setup)

(Process Variables)

(Diag/Service)

1.Tag

2.PV Unit&Damp

3.Range values

4.Snsr 1 config

5.Snsr 2 config

6.Snsr1 sensor s/n
7.Snsr2 sensor s/n

(Basic Setup)

1.Sensors

2.Signal condition

3.Output condition

4.Device information

1.Sensor 1 Review

2.Sensor 2 Review

3.Term temp Review

4.Out&Meter Review

5.Device Review

(Detailed setup)

1.Range values
2.Wrt protect menu

<Hot key>

Note :

Some parameters may appear or

disappear depending on the model,

suffix, option codes and setting of

parameters.

Figure 3.1 Menu Tree

Advertising