5 write protect, Write protect -13 – Yokogawa Wireless Temperature Transmitter YTA510 User Manual

Page 26

Advertising
background image

3. OPERATION

IM 01C50T01-01E

3-13

Process, Type:

Display Process Variable
name and Sensor Type in
turn.

Type, Wire:

Display Sensor Type and
the number of wires in
turn

Inhibit: Display none.

2) Disp Update

Update period of the display is
selected from Normal, Fast and
Slow.

NOTE

When the transmitter is used at temperatures
under -10

°

C, the response speed of the display

may become slow. It is recommended to set the
display speed to normal or slow in such case.

3.5.5 Write Protect

The write protect function is used to prevent unautho-
rized configuration data changes in the transmitter.
There are two ways to set this function; by hardwared
and by software, and hardware write protect function is
given priority.

Press Hot key and select “2. Wrt protect menu.”
Current status is shown in “1. Write protect.”

3.5.5.1 Write Protect Status

Press Hot key and select “2.Wrt protect menu.”
Current status is shown in “1.Write protect.”

Yes: Hardware or software write protect function

is activated. Under this status, any change
operation is denied with the message. [ In
write protect mode ] .

No : Neither protect function is activated.

3.5.5.2 Hardware Write Protect Function

Hardware write protect function is set up by Switch
(SW2) on the CPU assembly.

Pin position of SW2

Write Protect Status

Y

N

No

F0355.EPS

W P

Yes

Y

N

W P

SW2

SW2

SW2
Hardware Write Protect

SW1
Burnout output direction
upon hardware failure

CPU Assembly

Figure 3.3 SW2 setting

NOTE

1. Turn off the power supply before changing

the setting of SW2.

2. To change the SW2, it is necessary to

remove the LCD assembly with LCD model.
Refer to “ 6.3 Disassembly and Assembly” in
“YTA series Hardware Instruction Manual”
about the procedures.

Advertising