Yokogawa Wireless Temperature Transmitter YTA510 User Manual

Page 37

Advertising
background image

IM 01C50T01-01E

4-2

4. PARAMETERS LISTS

(1)PV (2)SV (3)TV (4)4V (5)PV,SV (6)PV,SV,TV
(7)PV,SV,TV,4V (8)Inhibit

(1)mA (2)% (3)mA,% (4)Inhibit

Show or Inhibit

Show or Inhibit

(1)Process (2)Type (3)Wire (4)Process,Type
(5)Type,Wire (6)Inhibit

Fast, normal, or slow.

Low, High, off, or user-setting value (mA or %).

Show the current setting of the output direction in
hardware failure which is set using jumper on a CPU
assembly.

(1)PV, (2)output in % range & current, (3)PV and output
in current.

Enable/disable the burst mode.

0 to 15.

Process variables.

% Output variable

4 to 20 mA Output variable

Terminal temperature variable

Output can be set from 4, 20 mA or the designated
value within 3.6 to 21.6 mA.

Check the transmitters’s status. If an error is detected,
the corresponsing message is displayed.

Reset the CPU and check the transmitters’s status.

Display of the result of self-test transmitter.

Show/not show warning messages. OFF or ON.

Up to 4 error histories are stored in EEPROM.

Maximum and Minimum value of PV, SV, TV, 4V and
Terminal Temperature during the operation.

Operation time from last power-on.

Un-intentional loss of during the operation may be
detected. START or STOP.

Displays the permit/protect status for setting changes.

Write protect status is released for 10 minutes when the
password is entered.

Setting a new password. 8 alpha numeric characters.

Show the status if the joker password was used.
Keep(not used), Break(used)

(1)V.R. / ZERO&GAIN (2)V.R. / ZERO (3)Temp /
ZERO&GAIN (4)Temp / ZERO

(1)On (2)Off (3)Clear

Give correction to the interpretation of a temperature
input to the characterization curve stored in a transmitter.

Adjust the output points of 4 mA and 20 mA.

Yokogawa
YTA110/YTA310/YTA320

Lower Limit for PV setting.
Upper Limit for PV setting.
Lower Limit for Sensor 1(2)
Upper Limit for Sensor 1(2)
Sensor1(2) serial number information

Process Disp

%/mA Disp

Error-No Disp

Bar graph

Matrix Disp

Disp update

Snsr burnout type

AO Alrm typ

Burst option

Burst mode

Poll addr

PV,SV,TV,4V

PV % rnge

PV AO

Term

Loop test

Self test

Master test

Status

Set warning enbl

Error log view

Max/Min log

Operate Time

Power Check

Write protect

Enable wrt
10 min

New password

Software seal

Input trimming
mode

Snsr1(2) trim act

S1(2)
trim zero/gain

D/A trim, Scaled
D/A trim
Destributor
Model
Dev.id
Final asmbly num
Universal rev
Fld dev rev
Software rev
PV LSL
PV USL
Snsr1(2) LSL
Snsr1(2) USL
Snsr1(2) Snsr s/n

Display
(see note 3)

Output

Monitoring

Maintenance

Adjustment

Referential
Information

Display select

Display update
period

Sensor burn-out
Output

Output in CPU
failure

Burst mode

Multi-drop mode

Process Variable

Output in %

Output in mA

Terminal
Temperature

Test Output

Self-diagnostics

Write Protect

Sensor trim
(Sensor1/2)

Analog output
trim

T0401_2.EPS

Item

Selection / Setting Range

Initial Setting

HART

Communicator

PV

mA

Show

Show

Process

Normal

High*

High*

disable

0

All OFF

STOP

NO

Note 3:

Appears only when Integral Indicator is specified.

Advertising
This manual is related to the following products: