4 changing the scale and scrolling the display, Changing the scale and scrolling the display -9, Ndisabling and enabling the auto-scale function – Yokogawa GC1000 Mark II Process Gas Chromatograph User Manual

Page 62: Nchanging the scale, Nscrolling the display

Advertising
background image

<4. Chromatogram Window>

4-9

IM 11B03G03-03E

4.4

Changing the Scale and Scrolling the

Display

There are three scales on the chromatogram display: X-axis [sec], Y-axis [mV], and temperature

[°C]. These scales can be changed to the desired ones using the commands in the [Scale] menu

or Enlarge/Reduce buttons.

n

Disabling and Enabling the Auto-scale Function

In the Chromatogram window scales are automatically set to display an overall view of the

chromatogram. This function is called “auto-scale”.

TIP

Changing the scale automatically disables the auto-scale function.

This section explains how to enable/disable the auto-scale function.

l

Procedure

(1) To disable the auto-scale, click on either the [Auto Scale] command in the [Scale] menu or

the Auto-scale button on the toolbar. This enables the auto-scale, causing the check mark (

) next to the [Auto Scale] command to disappear and the Autoscale button to appear not-

depressed.

(2) To enable the auto-scale, click again on either the [Auto Scale] command in the [Scale]

menu or the Auto-scale button on the toolbar. This enables the auto-scale function again,

causing the check mark ( ) next to the [Auto Scale] command to appear and the Auto-scale

button to appear depressed.

n

Changing the Scale

l

Enlarge/Reduce Buttons

Each clicking on the Enlarge/Reduce buttons changes the scale as shown in the following table.

buttons: reduces the scale

buttons: enlarges the scale

Scale

Available Scale Increments

X-axis scale (sec)

0.2→0.5→1→2→5→10→20→50→100→200→500→1000→

2000→5000→10000→20000→50000

Y-axis scale (mV)

0.1→0.2→0.5→1→2→5→10→20→50→100→200→500→1000

Temperature (°C)

10→50→100→200

The scales are common to both chromatograms and graphs of temperature data.

n

Scrolling the Display

Scrolling the display to view the chromatogram not shown on the display, typically when the

entire chromatogram cannot fit in the display because of, for example, scale enlargement.
The display can be scrolled using either of the following two methods.

l

Method 1

Click on the

,

, , or button at either end of the scroll bars. The chromatogram scrolls in

the direction of the arrow by one increment of the scale with each click.

4th Edition : Mar. 21, 2012-00