Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 50

Advertising
background image

50

IM 04L31A01-02E

Parameter

Value or Selections

Initial Value

Control mode

SingleLoopControl, CascadePrimaryLoop, CascadeSecondaryLoop,

SingleLoopControl

CascadeControl, ControlBackup, PVSwitching, PVAutoSelector,
PVHoldFunction, DualLoopControl, Temperature-Humidity,
Cascade-2Uni, PVSwitching-2Uni, or PVAutoSelector-2Uni

Control output

Relay, Voltage-pulse, Current-output, or On/Off-control

Relay

Alarm

Off, PH-H-E (PV high-limit alarm (energize)),

Off

PV-L-E (PV low-limit alarm (energize)),
Dev-H-E (Deviation high-limit alarm (energize)),
Dev-L-E (Deviation low-limit alarm (energize)),
Dev-H-D (Deviation high-limit alarm (deenergize)),
Dev-L-D (Deviation low-limit alarm (deenergize)),
Dev-HL-E (Deviation high & low limit alarm (energize)),
D-W-HL-E (Deviation within high & low limits alarm (energize)),
PV-H-D (PV high-limit alarm (deenergize)),
PV-L-D (PV low-limit alarm (deenergize)),
PV-H-ES (PV high-limit alarm (energize/hold)),
PV-L-ES (PV low-limit alarm (energize/hold)),
Dev-H-ES (Deviation high-limit alarm (energize/hold)),
Dev-L-ES (Deviation low-limit alarm (energize/hold)),
Dev-H-DS (Deviation high-limit alarm (deenergize/hold)),
Dev-L-DS (Deviation low-limit alarm (deenergize/hold)),
Dev-HL-ES (Deviation high & low limit alarm (energize/hold)),
D-W-HL-ES (Deviation within high & low limits alarm (energize/hold)),
PV-H-DS (PV high-limit alarm (deenergize/hold)),
PV-L-DS (PV low-limit alarm (deenergize/hold)),
TimeUp1 (Timer, upward detection, hours & minutes),
TimeDown1 (Timer, downward detection, hours & minutes),
TimeUp2 (Timer, upward detection, minutes & seconds),
TimeDown2 (Timer, downward detection, minutes & seconds),
Sensor (Sensor grounding alarm),
Prog-Diag (Self diagnosis output), FAIL (FAIL output),
SP-H (SP high-limit), SP-L (SP low-limit),
Out-H (Output high-limit), Out-L (Output low-limit),
Burnout1 (Heater burnout alarm 1), or
Burnout2 (Heater burnout alarm 2),

#2 Parameter address setting
Loop number

Ext1 to Ext16

Ext1

PV: Input

30001 to 39999, 300001 to 365535,

40003

40001 to 49999, or 400001 to 465535

SP : Setting

30001 to 39999, 300001 to 365535,

40004

40001 to 49999, or 400001 to 465535

OUT: Output

30001 to 39999, 300001 to 365535,

40005

40001 to 49999, or 400001 to 465535

Control mode

30001 to 39999, 300001 to 365535,

40008

40001 to 49999, or 400001 to 465535

Remote/Local

30001 to 39999, 300001 to 365535,

40008

40001 to 49999, or 400001 to 465535

Operation STOP/RUN

30001 to 39999, 300001 to 365535,

40205

40001 to 49999, or 400001 to 465535

Alarm status

30001 to 39999, 300001 to 365535,

40011

40001 to 49999, or 400001 to 465535

SP number

30001 to 39999, 300001 to 365535,

40010

40001 to 49999, or 400001 to 465535

PID number

30001 to 39999, 300001 to 365535,

40009

40001 to 49999, or 400001 to 465535

Auto reading

30001 to 39999, 300001 to 365535,

40008

40001 to 49999, or 400001 to 465535

List of Parameters