Wiring, Cx2000 – Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 7

Advertising
background image

7

IM 04L31A01-02E

Wiring

Input/Output terminals are arranged on the rear panel of the CX2000 as shown in the
figure below. The figure shows the case when option terminals are specified on the
model with 6 internal control loops and 20 measurement channels (CX2620). For the
wiring procedure of the control/measurement input/output, see chapter 2, “Installation
and Wiring” in the CX2000 User’s Manual (IM 04L31A01-01E) or the CX2000 Installation
and Connection Guide (IM 04L31A01-71E).

For a description on the connection of

communication interfaces such as the serial or Ethernet interface, see the CX2000
Communication Interface User’s Manual (IM 04L31A01-17E)

.

VIDEO OUT(VGA)

Measurement alarm

output (/A6 option)

Ethernet

Controllers (up to 16 loops)

10 universal measurement inputs

100 V to 240 VAC/
24 VDC/AC (/P1 option)

Magnet

switch

SSR

R3

R2

R1

Contact
output
6 outputs

Contact
input
6 inputs

Contact
output
6 outputs

Contact
input
6 inputs

Contact
output
6 outputs

Contact
input
6 inputs

Serial interface port

10 universal measurement inputs

10 universal measurement inputs

Option terminal

block (One

from below)

Measurement alarm output +

remote input/output

(/A6R option)

Four 24-VDC transmitter

power supplies

(/TPS4 option)

Control DIO expansion

(/CST1 option)

PLC

(such as the FA-M3

by Yokogawa)

PC

Controlling element

CX2000

Magnet

switch

Measurement alarm output +

FAIL/memory end output

(/A4F option)

Measurement alarm output +

FAIL/memory end output +

remote input/output (/A6R option)

Control output

terminal block
Loops 1 and 2

Control output

terminal block
Loops 3 and 4

Control output

terminal block
Loops 5 and 6

Analog control

input terminal block

Measurement

input terminal

block

Measurement

input terminal

block

Universal control output: for 2 loops

Select current, voltage pulse, or
relay output

Control contact input: 6 inputs
Control contact output

Relay output: 2 outputs
Transistor output: 2 outputs

Terminal Arrangement of the Analog Input Terminal Block for 6 Loop Control
(Conceptual Diagram. When PV/SP computation is OFF)
The following figure denotes the three terminals (/b, +/A, -/B) of a single column using a
single cell.

LOOP1

2

1

PV

(RSP)

(RSP)

PV

PV1

PV2

LOOP2

LOOP5

LOOP6

2

1

PV

1

PV

1

PV

(RSP)

PV

PV1

PV2

LOOP3

2

1

PV

(RSP)

(RSP)

PV

PV1

PV2

LOOP4

2

1

PV

(RSP)

PV

PV1

PV2

PV, PV1, PV2: measurement input, (RSP): remote input
(not used during program control), : unused terminal

During single-loop control
During cascade control
During loop control with
PV switching

[Control mode setting]

Terminal Arrangement of Loop 1 and 2 Control Output Terminal Block(When PV/
SP computation is OFF)

LOOP1

NO
NC

C

NO

C

2

NO
NC

C

LOOP2

CTRL OUT

mA

PULS

C

LOOP2

mA

PULS

C

C

5
6

C

3
4

4
5
6

1
2
3

LOOP1

CTRL OUT

DIGITAL OUT

DIGITAL OUT

DIGITAL IN

NO

C

1

Control current/

voltage pulse

output

Contact input

Transistor

output

Relay

contact output

Control relay

contact output