2 event output setting – Yokogawa Data Acquisition with PID Control CX2000 User Manual

Page 53

Advertising
background image

53

IM 04L31A01-02E

#7 Program control related (only when program control is ON)
<#1 Program parameter setting>

Parameter

Selectable Range or Selections

Initial Value

#1 Pattern initial setting
Program initial setting > Pattern number

1 to 4 (/PG1), 1 to 30 (/PG2)

1

Program initial setting > Segments

0 to 99

0

Program initial setting > Segment setting method

Time, Ramp

Time

Program initial setting > Pattern name

Up to 16 alphanumeric characters

Pattern 1

Program initial setting > Action loop > Loop 1 to 6

On/Off

Off

#2 Wait action setting
Wait action setting > Wait zone 1 to 5 >

Loop 1 to 6

On/Off

Off

> High, Low

EUS (100.0%) of the measurement span

1 digit

Wait action setting > Wait time

00:00:00 to 99:59:59

00:00:00

#3 Pattern start setting
Pattern start setting > Start target setpoint >

Loop 1 to 6

EU (0% to 100%) of the measurement span

–200.0

Pattern start setting > Start code

StartTargetSP, RampPV1 to RampPV6, TimePV,

StartTargetSP

#4 Program pattern setting
Program pattern setting > Segment number

1 to specified number of segments

1

Program pattern setting > Ramp/Soak select

Ramp, Soak

Ramp

Program pattern setting > Target setpoint >

Loop 1 to 6

EU (0% to 100%) of the measurement span

–200.0

Program pattern setting > Segment time

1

00:00:00 to 99:59:59

00:00:01

Program pattern setting > Ramp-rate time unit

2

Hour, Minute

Hour

Program pattern setting > Ramp

2

1 digit to EUS (100.0%) of the measurement span

1 digit

Program pattern setting > Segment PID group No. 1 to specified PID number

1

Program pattern setting > Segment shift action

Continue, HoldShift, LocalShift, ResetShift

Continue

Program pattern setting > Wait action

Off, Shift, Within

Off

Program pattern setting > Wait zone number

1 to 5

1

#5 Event setting
Event setting > Segment number

1 to specified number of segments

1

Event setting > Event kind

PVEvent, TimeEvent

TimeEvent

Event setting > TimeEvent 1 to 16

On1, On2, On3, Off

Off

Event setting > TimeEvent 1 to 16 >

On-time, Off-time

00:00:00 to 99:59:59

00:00:00

Event setting > PVEvent 1 to 16 > Loop

Off, 1 to 6

Off

Event setting > PVEvent 1 to 16 > Loop > Type

PV-High, PV-Low, Deviation-High, Deviation-Low, Deviation-H&L,

PV-High

Dev-within-H6L, SP-High, SP-Low, Output-High, Output-Low

Event setting > PVEvent 1 to 16 > Loop > Value

PV: EU (0% to 100%) of the measurement span

1370.0

Deviation: EUS (0% to 100%)

of the measurement span

1570.0

SP: EU (0% to 100%) of the measurement span

1370.0

Output: −5.0 % to 105.0 %

105.0 %

#6 Hysteresis (PV event)
Hysteresis (PV event) > PV event >

Hysteresis 1 to 16

0.0% to 10.0

0.5%

#7 Repeat action setting
Repeat action setting > Repeat action

Off, On, Repeat

Off

Repeat action setting > On > Repeat frequency

1 to 999

1

Repeat action setting > Repeat action

1 to specified number of segments

1

> Repeat start segment
Repeat action setting > Repeat action

1 to specified number of segments

1

> Repeat end segment

1

When [Time] is specified for the segment setting method.

2

When [Ramp] is specified for the segment setting method.

<#2 Event output setting*>

Parameter

Selectable Range or Selections

Initial Value

Event output > Pattern number

1 to 4 (/PG1), 1 to 30 (/PG2)

1

Event output > Event kind

PVEvent, TimeEvent

TimeEvent

Event output > Relay Output EV1 to 16

On, Off

Off

Event output > On EV1 to 16 > Number

DO001 to DO006, DO101 to DO106, DO201 to DO206,

DO001

RO001 to RO012, SW001 to SW036

Program pattern end signal > Relay Output

On, Off

Off

Program pattern end signal > On > Number

DO001 to DO006, DO101 to DO106, DO201 to DO206,

DO001

RO001 to RO012, SW001 to SW036

* With version 3.01, event output setting is included as item #6 within #1 Program pattern setting.

List of Parameters